beautypg.com

Blue Angel Pumps BCAPRPP50 User Manual

1/2 hp cast iron sewage pump, Description, Safety guidelines

background image

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

Description

This sewage pump is suitable for pumping
sewage, effluent, wastewater, and
groundwater with up to two inch solids.
The BRPP50T pump includes a wide angle
float switch that turns the pump on and
off as the fluid level rises and falls. The
BCAPRPP50 is provided with a “Cap
Switch” capacitive water sensor. When
water is detected, the pump will start
automatically. These pumps are intended
for use in domestic sewage lift stations.

Unpacking

Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return the
unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.

Operating Instructions

Models BRPP50T and BCAPRPP50

331303-002 1/08

Danger

indicates

an imminently hazardous situation
which, if not avoided, will result in
death or serious injury.

Warning

indicates

a potentially hazardous situation
which, if not avoided, could result in
death or serious injury.

Caution

indicates

a potentially hazardous situation
which, if not avoided, MAY result in
minor or moderate injury.

Notice
indicates

important information, that if not
followed, may cause damage to
equipment.

General Safety
Information

CALIFORNIA PROPOSITION 65

This

product

or its power cord may contain
chemicals known to the State of
California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.

GENERAL SAGETY INFORMATION
1. Know the pump application,

limitations, and po ten tial hazards.

Do not use to pump
flammable or explosive fluids
such as gasoline, fuel oil,
kerosene, etc. Do not use in flammable
and/or explosive atmospheres. Use pump
only with liquids compatible with pump
component materials. Failure to follow
this warning can result in personal
injury and/or property damage.

2. Make certain that the power source

(electric motor) conforms to the
requirements of the equipment.

Disconnect power before
servicing. If the power dis -
con nect is out of sight, lock
in the open po si tion and tag it to
prevent unexpected application of
power. Failure to do so could result in
fatal electrical shock!

3. Release all pressure within the system

before ser vic ing any component.

4. Drain all liquids from the system

before servicing.

This

pump

contains dielectric motor oil for motor
heat transfer. Care should be taken when
disposing of this oil. Do not use this
pump in ponds or fountains because the
motor oil can be harmful to aquatic life.

5. Secure the discharge line before

starting the pump. An unsecured
discharge line will whip, possibly

© 2008 Blue Angel™ Pumps

Specifications

BRPP50T

BCAPRPP50

Power supply requirements

120V, 60 hz

120V, 60 hz

Circuit requirements

15 amps (min)

15 amps (min)

Motor duty

Intermittent

Intermittent

Motor

120V, 1 Phase

120V, 1 Phase

Horsepower

1/2

1/2

Motor full load

6.3 amps

6.3 amps

Liquid temperature range

40°F to 120°F

40°F to 120°F

Max. operating position

45

o

from vertical

45

o

from vertical

Dimensions

14” x 12”

14” x 12”

Intake

2”

2”

Discharge

2” NPT female

2” NPT female

Cut-in level (factory set)

16”

11”

Cut-out level (factory set)

7.5”

7”

Differential

8.5”

4”

Switch

90

o

wide angle

“Cap Switch”

mechanical tether switch

capacitive water sensor

Power cord

18 gauge 3 Conductor

18 gauge 3 Conductor

with plug

with plug

Construction

Motor housing.......Cast iron
Volute ....................Cast iron
Impeller...................Glass reinforced PBT
Seal plate ...............Cast Iron
Shaft seal ...............Mechanical

GALLONS PER HOUR AT TOTAL

HEAD IN FEET

0

5

10

15

5700

4560

3240

900

Performance

1/2 HP Cast Iron
Sewage Pump

For parts, product & service information

visit www.blueangelpumps.com

Please read and save these instructions. Read carefully before attempting
to assemble, install, operate or maintain the product described. Protect
yourself and others by observing all safety information. Failure to
comply with instructions could result in personal injury and/or property
damage! Retain instructions for future reference.

This manual is related to the following products: