beautypg.com

Blue Angel Pumps BCAPSE50ODS User Manual

Sewage pump, Description, Unpacking

background image

© 2009 Blue Angel™ Pumps

330505-002 12/09

Sewage Pump

BCSE50T, BCSE50M

BCAPSE50 and BCAPSE50-2

Operating Instructions and Parts Manual

Please read and save these instructions. Read carefully before

attempting to assemble, install, operate or maintain the product

described. Protect yourself and others by observing all safety

information. Failure to comply with instructions could result in

personal injury and/or property damage! Retain instructions for

future reference.

Description

A sewage system consists of a pump,
control switch, and a ba sin for use in ap pli-
ca tions where less than six toilets (units)
are dis charged into the basin. The sys tem is
generally con trolled by a float switch with a
plug-in-plug which accepts the pump plug
and in turn plugs into a 120 volt outlet.
BCSE50T models utilize a wide angle
differential float switch that rises with the
liquid level and turns the pump on. As
the liquid level decreases the float lowers
and turns the pump off. The BCAPSE50
is provided with a solid-state electronic
capacitive water level control. When
water is detected, the pump will start
automatically. This pump is in tend ed for
use in do mes tic sewage lift stations. It is
suitable for pumping sewage, effluent,
wastewater, groundwater and other non
-ex plo sive, non-cor ro sive liquids with up
to 2 inch solids. Not approved for outdoor
use. Pump contains oil which is poisonous
to aquatic life. Do not use in ponds or
water features.

The Professional’s Line

For parts, product & service information

visit www.blueangelpumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes!

Attach it to this manual or file it for safekeeping.

Performance

GAllONS PER MINuTE AT TOTAl

hEAD IN fEET

5

10

15

113

90

33

unpacking

Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return
the unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.

Safety Guidelines

This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.

Danger indicates

an imminently

hazardous situation which, if not avoided,

WILL result in death or serious injury.

Warning indicates

a potentially

hazardous situation which, if not avoided,

COULD result in death or serious injury.

Caution indicates

a potentially

hazardous situation which, if not avoided,

MAY result in minor or moderate injury.

Notice indicates

important

information, that if not followed, may

cause damage to equipment.

General Safety

Information

CAlIfORNIA PROPOSITION 65

This product or its

power cord contains

chemicals known to the State of

California to cause cancer and birth

defects or other reproductive harm.

Wash hands after handling.

GENERAl SAfETy
1. Know the pump application,

limitations, and po ten tial hazards.

Do not

use to

pump flammable or

explosive fluids such

as gasoline, fuel oil,

kerosene, etc. Do not

use in a flammable and/or explosive

atmosphere. Use pump only with liquids

compatible with pump component

materials. Failure to follow this

warning can result in personal injury

and/or property damage.

Specifications

BCSE50M & BCSE50T

BCAPSE50 &
BCAPSE50-2

Power supply requirements

120V, 60 hz

120V, 60hz

Circuit requirements

15 amps (min)

15 amps (min)

Motor duty

Intermittent

Intermittent

Motor

120V, 1 Phase

120V, 1 Phase

Horsepower

1/2

1/2

Motor full load

8.7 amps

8.7 amps

Liquid temperature range

40°F to 120°F

40°F to 120°F

Max. operating position

45° from vertical

45° from vertical

Dimensions

14 inch x 12 inch

14 inch x 12 inch

Intake

2 inch

2 inch

Discharge

2 inch NPT female

2 inch NPT female

Cut-in level (factory set)

19 inch

11 inch

Cut-out level (factory set)

9 inch

3 inch

Differential

10 inch

7 inch

Switch

90° wide angle
mechanical tether switch

Capacitive water sensor

Power cord

16 gauge 3 conductor
with plug

16 gauge 3 conductor
with plug

Construction

Motor

body material .......... Cold rolled steel
Motor housing ...................... Cast iron
Volute .................................... Cast iron
Impeller .............. Glass reinforced PBT
Seal plate .............................. Cast Iron
Shaft seal ........................... Mechanical

This manual is related to the following products: