Programming a tr3 endpoint - rtr only, Programming a tr3 endpoint - rtr only 14, Programming a tr3 endpoint - rtr only” on – Badger Meter GALAXY User Manual
Page 14
Programming a TR3 Endpoint - RTR only
NOTE:
N
The Program function is for RTR endpoints only If you try to program an encoder endpoint, the reading you enter
will be replaced by the actual reading
1 With the TR3 IR tab selected on the programmer screen, align the optical read head of the IR cable with the TR3
endpoint and tap the Read button
2 Tap Reading to activate the field
3 Tap at the end of the current entry in the Reading field Then use the DELETE key on the keypad to erase the
current entry
4 Use the keypad to enter the new reading from the odometer on the encoder register
5 Align the optical read head of the IR cable with the IR port of the TR3 endpoint and tap Program.
Result: The message "Please Wait: IR Wakeup in Progress" is displayed. When the message disappears, the endpoint is
programmed to start at the reading you entered.
Figure 19: Reading field activated
Figure 20: New read programmed
GALAXY® Programmer – Handheld Programming Software for TR3 and TR2 Endpoints
Page 14
February 2013