Force RF

The Force RF command is used to force an endpoint transmission, most commonly to test installation success An initial read

must be performed prior to forcing a transmission

1 To force an endpoint transmission, align the optical

read head of the IR cable with the IR port of the TR3

endpoint and tap the Force RF button




Result: A warning screen is displayed as shown in

Figure 13.

Figure 12: Force RF

2 Tap Yes to continue

Result: Once a transmission has been sent, the display

returns to the TR3 Programmer screen.

NOTE:

N

Tap No if you want to cancel the

Force RF command

Figure 13: Force RF Warning screen

3 If the Force RF command is unsuccessful, one of two

transmission failed screens is displayed, depending

on whether there is a partial response or no

response from the endpoint
If either screen is displayed, tap OK to close the

transmission failed screen and repeat steps 1 and

2 until you get a successful transmission Refer to

“IR Reading Error” on

page 22

for additional help

NOTE:

N

Allow at least 30 seconds between Force RF

commands