West Control Solutions KS 800 CANopen Interface Manual User Manual
Page 26
KS 800 CAN-Interface
Column "as from firmware":
C = This datum exists already from operating version 1, however, it was
subject to change (extension) in the course of development.
N = This datum was added as from the specified operating version.
Index
(hex)
Object
(symbolic
name)
Name
Type
Attri-
bute
as
from
firm-
ware
FB unit
Process data fct.no.0
2001
VAR
Status 1Unit-State1
Unsigned8
ro
1.0
2002
VAR
Basic hardware options HWbas
Unsigned16
ro
1.0
2003
VAR
SW options SWopt
Unsigned16
ro
1.0
2004
VAR
SW code no. SWCode
Unsigned16
ro
1.0
2005
VAR
SW version SWVersion
Unsigned16
ro
1.0
2006
VAR
Operating version OPVers
Unsigned16
ro
1.0
2007
VAR
EEPROM version EEPVers
Unsigned16
ro
1.0
2008
VAR
Configuration mode selection OPMod
Unsigned8
rw
1.0
2009
VAR
Self-tuning stop/start of all group controllers
OStartg
Unsigned8
rw
1.0
200A
VAR
Local data change flag reset
Unsigned8
rw
1.0
Parameter and configuration data fct. no. 0
200B
VAR
Baudrate COM 1 C900
Unsigned16
rw
*
1.0
200C
VAR
Controller address Adr1
Unsigned16
rw
*
1.0
200D
VAR
Mains frequency 50/60
Unsigned8
rw
*
1.0C
200E
VAR
Baudrate COM 2 C900 (CAN baudrate)
Unsigned16
rw
*
1.0
200F
VAR
Controller address Adr2 (CAN Node ID)
Unsigned16
rw
*
1.0
2010
VAR
Releasing the cooling function for Water Co-
oling
FixedPoint1
rw
*
2.0
2011
VAR
Heating-current reset / quicktest
Unsigned8
rw
4.0
Process data Fct. no. 2
2020
VAR
Status alarm outputs State_alarm_out
Unsigned8
ro
1.0
2021
VAR
Status dig. inputs/outputs State_dio
Unsigned8
ro
1.0
Parameter and configuration data fct.no. 2
2022
VAR
Main config. C500
Unsigned16
rw
*
1.0
2023
VAR
Main config. C530
Unsigned16
rw
*
1.0
2024
VAR
Allocation HC/leakage current C151
Unsigned16
rw
*
1.0C
2025
VAR
Heating current cycle Hccycl
Unsigned16
rw
*
1.0
2026
VAR
Span end for HC input HC 100
FixedPoint1
rw
*
1.0
26
9499 040 49511