Connection of output OUT LC

4

Relay (250V/2A), potential-free changeover contact

Connection of outputs OUT1/2

5

Relay outputs 250V/2A normally open with common contact connection

a

The pre-alarms (OUT1/2) must be used only for signalling and not for control
purposes!

a

The pre-alarm OUT2 is available only if configured as TW!

TB40-1 connecting example:

a

CAUTION:

Using a temperature limiter is recommendable in systems where overtemperature
implies a fire hazard or other risks.

Electrical connections

Connecting diagram TB 40-1 temperature limiter TB