West Control Solutions MRC 7000 Recorder Manual User Manual
Page 12
12
RTD LEAD RESISTANCE
RTD lead length can affect instrument accuracy, since the size (gauge) and length of the wire
affect lead resistance.
To determine the temperature error resulting from the lead length resistance, use the follow-
ing equation:
Terr = TLe * L
where;
TLe = value from Table 3 if 3 wire RTD or Table 4 if 2 wire RTD
L = length of lead wire in thousands of feet
TABLE 3
3 Wire RTD
AWG No.
Error
°
C
Error
°
F
10
+/-0.04
+/-0.07
12
+/-0.07
+/-0.11
14
+/-0.10
+/-0.18
16
+/-0.16
+/-0.29
18
+/-0.26
+/-0.46
20
+/-0.41
+/-0.73
24
+/-0.65
+/-1.17
TABLE 4
2 Wire RTD
AWG No.
Error
°
C
Error
°
F
10
+/-5.32
+/-9.31
12
+/-9.31
+/-14.6
14
+/-13.3
+/-23.9
16
+/-21.3
+/-38.6
18
+/-34.6
+/-61.2
20
+/-54.5
+/-97.1
24
+/-86.5
+/-155.6
Example:
An application uses 2000 feet of 18 AWG copper lead wire for a 3 wire RTD sensor. What is
the worst case error due to this leadwire length?
Terr = TLe * L
TLe = +/-.46 (
°
F/1000 ft) from Table 3
Terr = +/-.46 (‡F/1000 ft) * 2000 ft
Terr = +/-0.92
°
F
- 2300 (18 pages)
- 3300 (2 pages)
- 4100+ (177 pages)
- N4100 (79 pages)
- N4400 (38 pages)
- N6500 (2 pages)
- N6600 (114 pages)
- N8800 (88 pages)
- N8840 (90 pages)
- 9300 (2 pages)
- 9500 (24 pages)
- D280-1 (49 pages)
- KS 40-1 (60 pages)
- KS 40-1 Burner (40 pages)
- KS 45 (76 pages)
- KS 50-1 (72 pages)
- KS 90-1 (84 pages)
- KS 90-1 Programmer manual (84 pages)
- KS 94 (44 pages)
- ProVU 4 (184 pages)
- Pro-16 (88 pages)
- Pro-8 (72 pages)
- Pro-4 (84 pages)
- ProEC44 (274 pages)
- CI 45 (60 pages)
- SG 45 (56 pages)
- DataVU 5 (136 pages)
- DataVU 7 (208 pages)
- MRC 5000 Controller Manual (32 pages)
- MRC 5000 Recorder Manual (32 pages)
- MRC 7000 Controller Manual (74 pages)
- MRC 7000 Profiler Manual (84 pages)
- MRC 8000 (76 pages)
- MRC 9000 (318 pages)
- N8080 (for 1xxx) (40 pages)
- N8080 (for 2xxx) (39 pages)
- TB 40-1 Temperature Limiter (32 pages)
- TB 40-1 Temperature Monitor (32 pages)
- TB 45 Temperature Limiter (51 pages)
- TB 45 Temperature Monitor (52 pages)
- CALogix (44 pages)
- KS 800 Operating Instructions (36 pages)
- KS 800 ISO1745 Interface Manual (34 pages)
- KS 800 Profibus Interface Manual (52 pages)