beautypg.com

5 conduit/cable installation, 6 detector/source mounting, 1 tilt kit p/n 799640 – Spectrex Xenon 700 SIL Open-Path Gas Detection System User Manual

Page 45: 2 detector/source installation, Conduit/cable installation, Detector/source mounting, Tilt kit p/n 799640, Detector/source installation, Table 14: tilt mount kit

background image

TM 799200 Rev (C), January 2014

Conduit/Cable Installation

33

5.5

Conduit/Cable Installation

The conduit and cable installation must comply with the following
guidelines:

1

To avoid water condensation in the detector, install the Detector with the
conduits/cable entries facing downwards

2

Use flexible conduits/cables for the last portion connecting to the
detector

3

When pulling the cables through the conduits, ensure that they are not
tangled or stressed. Extend the cables about 12 inches (30cm) beyond
the Detector location to accommodate wiring after installation.

4

After the conductor cables have been pulled through the conduits,
perform a continuity test

5.6

Detector/Source Mounting

The Detector Source should be mounted with the Tilt Mount Kit, Model
799640. The Tilt enables the Detector to be rotated up to 45º in all
directions and fine alignment of up to 3º.

5.6.1 Tilt Kit P/N 799640

The following contents are included with the Tilt Mount Kit:

Table 14: Tilt Mount Kit

Item

Qty

Type/Model

Tilt Mount

1

799220

Screw

1

5/16” – 18 UNC x 3/4”

Spring Washer

1

No. 5/16”

5.6.2 Detector/Source Installation

(Figure 4 and Figure 5)

To install the Detector/Source:

1

Place the Tilt Mount holding plate (item 1) in its designated location and
secure it with (4) fasteners through four (4) holes dia. 8.5mm.

Notes:
1. Skip this step if the Tilt Mount is already installed.
2. Detector removal for maintenance purpose does not require Tilt Mount
removal.

2

Place the Detector, with its conduit/cable inlets pointing downwards on
the Detector holding plate of the Tilt Mount (item 2). Secure the
Detector with 5/16”-18UNC x 3/4" screw with No. 5/16” spring washers
(9,10) to the Tilt Mount. Use ¼” Hex Key for 5/16” screw (item 9).

3

Repeat 1 – 2 to install the Source.