3 mechanical specifications, 4 environmental specifications, 1 high temperature – Spectrex Xenon 700 SIL Open-Path Gas Detection System User Manual
Page 38: 2 low temperature, Mechanical specifications, Environmental specifications, High temperature, Low temperature
SafEye
TM
Xenon 700S SIL Gas Detector
26
Environmental Specifications
4.3
Mechanical Specifications
Enclosure:
The Detector, Source and tilt mount are St. St.
316 Electro chemical and passivized coating.
Explosion Proof:
ATEX Ex II 2(1) G, Ex d e ia [ia Ga] IIC T5 Gb Ta
Temp -40°F (-40°C) to 131°F (55°C)
IECEx Ex II 2(1) G, Ex d e ia [ia Ga] IIC T5 Gb Ta
Temp -40°F (-40°C) to 131°F (55°C)
Water and Dust
Tight:
IP 66 and IP 67
NEMA 250 type 6p
Electrical Modules: Conformal coated
Electrical
Connection:
(Two options - specified at time of order)
2 X M25 (ISO)
2 X 3/4” - 14NPT conduits
Dimensions:
Detector 8.2 x 5.7 x 6 in
(210 x 145 x 154mm)
Source
10 x 5.3 x 6.9 in (255 x 135 x 175mm)
Tilt Mount 4.7 x 4.7 x 5.5 in (120 x 120 x 140mm)
Weight:
Detector
9.2 lb.
(4.2 kg)
Source
10.1 lb.
(4.6 kg)
Tilt Mount 4.2 lb.
(1.9 kg)
4.4
Environmental Specifications
The SafEye system is designed to withstand harsh environmental conditions.
The Source and Detector units compensate for adverse conditions while
maintaining accuracy.
4.4.1 High Temperature
Designed to meet MIL-STD-810C, method 501.1 procedure II
Operating Temperature:
+131 ºF (+55 ºC)
Storage Temperature:
+149 ºF (+65 ºC)
4.4.2 Low Temperature
Designed to meet MIL-STD-810C, method 502.1, procedure I
Operating Temperature:
-4 ºF (-20 ºC)
Storage Temperature:
-40 ºF (-40 ºC)