4.4.3 Humidity

Designed to meet MIL-STD-810C, method 507.1, procedure IV relative
humidity of up to 95% for the operational temperature range.

4.4.4 Salt and Fog

Designed to meet MIL-STD-810C, method 509.1 procedure I. Exposure to a
5% salt solution for 48 hours.

4.4.5 Water and Dust

IP67 per EN60529

IP66 per EN60529

Dust:

Totally protected against dust

Liquids:

Protected against immersion between 15
cm and 1m in depth. Protected against

all water jets from all directions.

4.4.6 Shock and Vibration

Vibration:

Designed to meet MIL-STD-810C,
method 514.2, procedure VIII.

Mechanical Shock:

Designed to meet MIL-STD-810C,
method 516.1, procedure I.

4.4.7 Electromagnetic Compatibility (EMC):

This product is in conformance with EMC directive 89/336/EC.

Radiated Emission:

EN61000-6-3

Conducted Emission:

EN61000-6-3

Radiated Immunity:

EN61000-4-3

Conducted Immunity:

EN61000-4-6

ESD:

EN61000-4-2

Burst:

EN61000-4-4

Surge:

EN61000-4-5