beautypg.com

5 models and types, Models and types, Table 3: model numbers and installation distances – Spectrex Xenon 700 SIL Open-Path Gas Detection System User Manual

Page 21

background image

TM 799200 Rev (C), January 2014

Models and Types

9

2.5

Models and Types

Series 700S offers 2 families of detected gases:

Models 701S, 702S and 703S used for methane, LPG and gases mixture
for most offshore and onshore applications.

Models 721S, 722S and 723S used for ethylene only.

Table 3 describes the installation distances for each of the Series 700S
models.

Table 3: Model Numbers and Installation Distances

Model

No.

Detector

Source

Min.

Installation

Distance

Max.

Installation

Distance

701S

XDSS-C-111XX

XSS-C-11X

13 ft. (4 m)

65 ft. (20 m)

702S

XDSS-C-112XX

XSS-C-11X

50 ft. (15 m)

230 ft. (70 m)

703S

XDSS-C-113XX

XSS-C-12X 165 ft. (50 m) 459 ft. (140m)

721S

XDSS-C-121XX

XSS-C-11X

13 ft. (4 m)

65 ft. (20 m)

722S

XDSS-C-122XX

XSS-C-11X

50 ft. (15 m)

230 ft. (70 m)

723S

XDSS-C-123XX

XSS-C-12X 165 ft. (50 m) 459 ft. (140m)

The 700S Series has 3 wiring options:

Option 1: Power, Alarm Relay, Fault Relays, 0-20mA

Option 2: Power, Alarm Relays, Fault Relays, Accessory Relay

Option 3: Power, Alarm Relay, RS-485, 0-20mA, RS-485 RTN (default)

Note: SIL2 covers only 0-20mA outputs.

The wiring option must be set at the factory; cannot be changed at
customer facility.