7.1.6 requesting data from pcs, 7 examples – SHIMPO CEG-2000 User Manual
Page 25

-22-
7.1.6
Requesting data from PCs
(1) Latch (data hold) command for the measured value
Send command byte “E” (45H). This micrometer will hold the measured value.
(2) Latch release command
Send command byte “R” (52H). This micrometer will release its hold on the
measured value.
(3) Request for measured value
Send command byte “D” (44H). This micrometer will send the data in 4 above
to the PC.
7.1.7
Examples
I
T
E
M
1
I
T
E
M
2
I
T
E
M
3
CR LF
49
Text
ASCII cord
54 45 4D 31
49 54 45 4D 32
49 54 45 4D 33
0D
G
47
J
4A
N
4E
20
45
53
55
20
4F
4E
20
20
20
20
K
47
O
4F
20
20
35
2E
32
31
20
20
20
20
20
20
G
47
N
4E
2D
20
30
2E
35
32
2D
20
E
S
U
O
5
.
2
1
0
.
5
2
N
20
20
20
0A
See also other documents in the category SHIMPO Tools:
- DT-361 (36 pages)
- DT-365E (28 pages)
- DT-311A (4 pages)
- DT-311J (12 pages)
- DT-315AEB (4 pages)
- DT-315P (17 pages)
- DT-326 (35 pages)
- DT-725 (4 pages)
- DT-900 (33 pages)
- ST-1000 (2 pages)
- ST-5000 (4 pages)
- SG-300 (2 pages)
- DT-721 (4 pages)
- DT-329 (32 pages)
- DT-105A (2 pages)
- DT-107A (2 pages)
- MT-100 (4 pages)
- MT-200 (4 pages)
- PT-110 (2 pages)
- DT-105A-S12 (2 pages)
- DT-205L (4 pages)
- DT-205L-S12 (4 pages)
- DT-207L (4 pages)
- DT-207L-S12 (4 pages)
- DT-209X (68 pages)
- DT-5TXR (20 pages)
- DT-5RL-1 (2 pages)
- DT-5TP (8 pages)
- DT-601CG (54 pages)
- FGV-XY-Series (32 pages)
- FGE-X (8 pages)
- FGE-HX (8 pages)
- FG-3000 (8 pages)
- FG-7000-Series (8 pages)
- DFS-series (20 pages)
- DRI-series (20 pages)
- EM-series (2 pages)
- FGE-series (4 pages)
- FGV-series (4 pages)
- FGE-H-series (4 pages)
- FGV-H-series (4 pages)
- MF Series (2 pages)
- MFD_Series (2 pages)
- FGS-100E (20 pages)
- FGS-100-PXL (7 pages)