Chapter 4. Troubleshooting

61200176L2-1

Express 4100/4110 User Manual

4-5

7.

If the Loop Status in the Express 4100/4110 Status Menu continuously
reads Register SPID #2, the Express 4100/4110 has completely initial-
ized the first phone number but is unable to establish logical layer 3 for
the second phone number. The problem is in one or both of the follow-
ing places:

The Express 4100/4110 software setup

The telephone service provider’s software setup

To isolate the problem, perform the following procedure:

A. Ensure the line is multipoint with two phone numbers.

B. Ensure that the Express 4100/4110 is set up with the correct SPID

and LDN. For example:

SPID1 = 20572270460101
SPID2 = 20572270470101
LDN 1 = 7227046
LDN 2 = 7227047

C. Try swapping SPID1 with SPID2 and LDN1 with LDN2. Deter-

mine if the problem is with the second phone number or the quan-

tity of phone numbers.

D. If possible, try another piece of functioning ISDN equipment with

a U-interface on the line.

E. With the Express 4100/4110 connected to the line and powered

up, talk to your service provider’s repair group and tell them you

have an ISDN basic rate line that appears physically okay but is

unable to register its SPIDs. Ask them to check the line transla-

tion, ensure the line supports dynamic TEI allocation, and verify

the SPIDs. Tell them that you have an NT1 and terminal adapter

device connected to the line.