beautypg.com

Technical data – KROHNE BW 25 EN User Manual

Page 47

background image

TECHNICAL DATA

8

47

BW25

www.krohne.com

09/2010 - 4000432302 MA BW25 R05 en

M10 process variable

Values [%]

Signal output [mA]

Over range

+105 (± 1%)

20.64...20.96

Device error identification

> 110

> 21.60

Maximum

112.5

22

Multi-drop operation

-

4.5

Min. U

ext.

12 VDC

M10 binary output

Two binary outputs

Galvanically isolated

Operating mode

Switch output

NAMUR or open collector

Configurable as

switch contact or pulse

output

Open / closed or max. 10 P/s

NAMUR switch output

Power supply U

ext.

8 VDC

Signal current

> 3 mA switching value not

reached;

< 1 mA switching value

reached

Switch output, open collector

Power supply

8...30 VDC

Pmax

500 mW

Imax

100mA