beautypg.com

Operation – KROHNE BW 25 EN User Manual

Page 33

background image

OPERATION

6

33

BW25

www.krohne.com

09/2010 - 4000432302 MA BW25 R05 en

DDs ("driver") for HART

®

Tools, process control (e.g. Siemens PDM or AMS) PACTware™ and

HART

®

DTMs are available at the KROHNE Download Center.

FRAM WRITE

FAULT

Internal

communication error

Error

Check whether the display is plugged in

correctly and restart the device. If the error

occurs again: send the device back to the

manufacturer with an indication of the error.

ROM/FLASH

ERROR

Memory error

detected during self-

test.

Error

Restart the device. If the error occurs again:

send the device back to the manufacturer with

an indication of the error.

RESTART OF

DEVICE

A device restart has

taken place

Information

The device has been restarted using menu

item 1.5.2 since the last time the error

messages were reset.

MULTIDROP

MODE

The HART® multidrop

mode is activated.

The current output is

set to a fixed value of

4.5 mA.

Information

The HART

®

multi-drop mode is activated by

selecting a polling address not equal to 0

using menu item 3.9. Polling address 0

reactivates the current output.

CRYSTAL OSC

FAULT

Internal error in

device

Error

The device must be sent back to the

manufacturer with an indication of the error.

REF VOLTAGE

FAULT

SENSOR A FAULT

SENSOR B

FAULT

MEMORY

CORRUPTION

Internal memory

error, caused by a

hardware or software

problem

Error

Restart the device; if the error occurs again

the device must be sent back to the

manufacturer with an indication of the error.

AO FIXED

The current output is

set to a fixed value.

Information

The current output is fixed and does not

reflect the measured value. This is the case in

multidrop mode, with current output
test/calibration using the menu or HART

®

AO SATURATED

Current output

saturated

Information

The current output is saturated at 20.4 or 22.0

mA (depending on whether the alarm current

is activated or deactivated in menu item 3.12),

and is no longer coupled with the measured

value.

Error message

Description

Category

Remedy

MA_BW25_R05_en_432302_PRT.book Page 33 Tuesday, September 28, 2010 8:17 AM