3.4 Installation

The sealing surface of the tank flange must be horizontal to ensure the perfect function of the
level measurement unit.

• Insert the spring suspension pin in the flange system and secure it with a retaining ring 1.
• Install the retaining ring 1 properly and check for a correct seat all round.
• Place the seal on the tank flange.
• Suspend the displacer body on the spring suspension pin.
• Tighten the locking elements of the quick-action lock 2 (standard) or, with the variant, 3 and

4 and check for a tight fit.

• Insert the displacer element and the spring suspension pin into the tank through the tank

flange or into the preinstalled bypass chamber.

• Tighten the flange connection.

1 Lock ring
2 Quick-action lock
3 Retaining screw
4 Cover stop