Technical data, 2 technical data – KROHNE BW 25 EN User Manual
Page 43
TECHNICAL DATA
8
43
BW25
www.krohne.com
09/2010 - 4000432302 MA BW25 R05 en
8.2 Technical data
INFORMATION!
•
The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local representative.
•
Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).
Measuring system
Application range
Level measurement
Operating method / measuring principle
Displacement principle
Measured value
Level, separating layer
Measuring accuracy
Standard
< 1.5% full scale value
Min. measuring range
0.3 m / 12"
Max. measuring range
6 m / 20 ft
Medium
Liquids
Density
≥ 0.45 kg/l / 28.1 lbs/ft
3
Materials
Housing
Aluminium with artificial resin coating
Housing option
Stainless steel (indicator M9)
Displacer rod
Stainless steel 1.4404
Displacer rod option
Titanium
Spring
Stainless steel 1.4571 (T
m
< 100°C / 212°F)
Spring option
ATS 340 (T
m
> 100°C / 212°F)
Flange
Stainless steel 1.4404
Pressure sleeve
Stainless steel 1.4404
Process connections
Max. operating pressure
40 bar - optional to 400 bar / 580 - optional 5802
psig
Standard flange
DN50 - PN40 / 2" ASME 300 lbs
Optional flange
...DN100 - ...PN400 / …4" ASME ...2.500 lbs
Approvals
ATEX, indicator M9 with electrical installations
Cat. II 1/2G, EEx ia IIC T6
ATEX, indicator M10
Cat. II 1/2G, EEx d IIC T6
ATEX, indicator M9 without electrical installations
for Zone 0 tanks
Cat. II 1/2 Gc
for Zone 1.21
Cat. II 2 GD
for Zone 2.22
Cat. II 3 GD
MA_BW25_R05_en_432302_PRT.book Page 43 Tuesday, September 28, 2010 8:17 AM