beautypg.com

Technical data – KROHNE BW 25 EN User Manual

Page 45

background image

TECHNICAL DATA

8

45

BW25

www.krohne.com

09/2010 - 4000432302 MA BW25 R05 en

Technical data, indicator M9
M9 cable glands

M9 limit switches

Cable gland

Material

Cable diameter

M 16x1.5 Standard

PA

3...7 mm

0.118...0.276"

M20 x 1.5

PA

8...13 mm

0.315...0.512"

M 16x1.5

Nickel-plated brass

5...9 mm

0.197...0.355"

M20 x 1.5

Nickel-plated brass

10...14 mm

0.394...0.552"

Terminal connection

2.5 mm

2

Limit switch

I7S23,5-N

SC3,5-N0

SJ3,5-SN

1

SJ3,5-S1N

1

SB3,5-E2

NAMUR

yes

yes

yes

no

Connection type

2-wire

2-wire

2-wire

3-wire

Switching element

function

NC contact

NC contact

NO contact

PNP NO contact

Nominal voltage U

0

8 VDC

8 VDC

8 VDC

10...30 VDC

Pointer vane not detected

≥ 3 mA

≥ 3 mA

≤ 1 mA

≤ 0.3 VDC

Pointer vane detected

≤ 1 mA

≤ 1 mA

≥ 3 mA

U

B

- 3 VDC

Continuous current

-

-

-

max. 100 mA

No load current I

0

-

-

-

≤ 15 mA

1 safety oriented

M9 current output ESK2A

Terminal connection

2.5 mm

2

Power supply

12...30 VDC

Min. power supply for HART TM

18 VDC

Measuring signal

4.00...20.00 mA = 0...100% level value in 2-wire technology

Power supply influence

< 0.1%

Dependence on external resistance

< 0.1%

Temperature influence

< 5 uA / K

Max. external resistance / load

800 Ohm (30 VDC)

Min. load for HART TM

250 Ohm

Software firmware version

02.14

Ident No:

3210680500

MA_BW25_R05_en_432302_PRT.book Page 45 Tuesday, September 28, 2010 8:17 AM