Technical data, indicator M9
M9 cable glands
M9 limit switches
Cable gland
Material
Cable diameter
M 16x1.5 Standard
PA
3...7 mm
0.118...0.276"
M20 x 1.5
PA
8...13 mm
0.315...0.512"
M 16x1.5
Nickel-plated brass
5...9 mm
0.197...0.355"
M20 x 1.5
Nickel-plated brass
10...14 mm
0.394...0.552"
Terminal connection
2.5 mm
2
Limit switch
I7S23,5-N
SC3,5-N0
SJ3,5-SN
1
SJ3,5-S1N
1
SB3,5-E2
NAMUR
yes
yes
yes
no
Connection type
2-wire
2-wire
2-wire
3-wire
Switching element
function
NC contact
NC contact
NO contact
PNP NO contact
Nominal voltage U
0
8 VDC
8 VDC
8 VDC
10...30 VDC
Pointer vane not detected
≥ 3 mA
≥ 3 mA
≤ 1 mA
≤ 0.3 VDC
Pointer vane detected
≤ 1 mA
≤ 1 mA
≥ 3 mA
U
B
- 3 VDC
Continuous current
-
-
-
max. 100 mA
No load current I
0
-
-
-
≤ 15 mA
1 safety oriented
M9 current output ESK2A
Terminal connection
2.5 mm
2
Power supply
12...30 VDC
Min. power supply for HART TM
18 VDC
Measuring signal
4.00...20.00 mA = 0...100% level value in 2-wire technology
Power supply influence
< 0.1%
Dependence on external resistance
< 0.1%
Temperature influence
< 5 uA / K
Max. external resistance / load
800 Ohm (30 VDC)
Min. load for HART TM
250 Ohm
Software firmware version
02.14