Technical data, 3 sizing – KROHNE TIDALFLUX 4300 F EN User Manual
Page 35
TECHNICAL DATA
7
35
TIDALFLUX 4300 F
www.krohne.com
06/2010 - 4000970001 - TIDALFLUX 4300 F R01 en
7.3 Sizing
Flow and velocity at 100% level, gravity fed, metric values
INFORMATION!
These tables state the flowrate in a partially filled pipe, dependant on slope, filling level, inner
diameter and friction factors of the pipe. The values are calculated according the Manning-
Strickler equation. The results do not consider: deposits, profile distortion, backwater, friction of
air and the slightly smaller inner diameter of the TIDALFLUX.
DN
Steel / PVC
Smooth concrete
Concrete
Nominal
size
v [m/s]
Q [m3/h]
v [m/s]
Q [m3/h]
v [m/s]
Q [m3/h]
slope 0.5%
200
0.96
109
0.86
97
0.58
66
250
1.11
196
1.00
177
0.67
118
300
1.26
321
1.13
288
0.75
191
350
1.39
481
1.25
433
0.84
291
400
1.52
688
1.37
620
0.91
412
500
1.77
1251
1.59
1124
1.06
749
600
2.00
2036
1.8
1832
1.2
1221
700
2.21
3062
1.99
2757
1.33
1843
800
2.42
4379
2.18
3945
1.45
2624
900
2.62
6000
2.35
5382
1.57
3596
1000
2.81
7945
2.53
7153
1.68
4750
1200
3.17
12906
2.85
11603
1.9
7736
1400
3.51
19451
3.16
17511
2.11
11693
1600
3.84
27794
3.45
24971
2.3
16647
slope 1.0%
200
1.36
154
1.22
138
0.81
92
250
1.57
277
1.42
251
0.94
166
300
1.78
453
1.6
407
1.07
272
350
1.97
682
1.77
613
1.18
409
400
2.15
973
1.94
878
1.29
584
500
2.5
1767
2.25
1590
1.5
1060
600
2.82
2870
2.54
2585
1.69
1720
700
3.13
4336
2.82
3907
1.88
2605
800
3.42
6189
3.08
5573
2.05
3709
900
3.7
8474
3.33
7626
2.22
5084
1000
3.97
11225
3.57
10094
2.38
6729
1200
4.48
18240
4.03
16408
2.69
10952
1400
4.97
27542
4.47
24771
2.98
16514
1600
5.43
39302
4.89
35394
3.26
23596