7

TECHNICAL DATA

34

TIDALFLUX 4300 F

www.krohne.com

06/2010 - 4000970001 - TIDALFLUX 4300 F R01 en

Electrical connections

General

Electrical connection is carried out in conformity with the VDE 0100

directive "Regulations for electrical power installations with line

voltages up to 1000 V" or equivalent national specifications.

Power supply

Standard: 110 / 220 VAC (-15% / +10%), 50/60 Hz

settable by switch

Option: 24 VAC, 50/60 Hz

Power consumption

14 VA

Field current cable

Shielded cable must be used, no part of delivery.

Signal cable

DS 300 (type A)

DS 300 (type A)

DS 300 (type A)

DS 300 (type A)

Max. length: 600 m / 1950 ft (dependent on electrical conductivity).

BTS 300 (type B)

BTS 300 (type B)

BTS 300 (type B)

BTS 300 (type B)

Max. length: 600 m / 1950 ft

Data interface cable

For transmission of measured level to IFC 300 F.

Shielded Liycy cable, 3 x 0.75 mm

2

Cable entries

2x M20 x 1.5

1x M20 x 1.5 EMC type

1x PG9 EMC type

Approvals and certificates

CE

CE

CE

CE

This device fulfills the statutory requirements of the EC directives.

The manufacturer certifies successful testing of the product by

applying the CE mark.

Electromagnetic compatibility

Directive: 2004/108/EC, NAMUR NE21/04

Harmonized standard: EN 61326-1 : 2006

Low voltage directive

Directive: 2006/95/EC

Harmonized standard: EN 61010 : 2001

Pressure equipment directive

Directive: 97/23/EC

Category I, II or SEP

Fluid group 1

Production module H

Hazardous areas

Hazardous areas

Hazardous areas

Hazardous areas

ATEX

Option: Ex zone 2

Ex zone 1 in preparation

Other approvals and standards

Other approvals and standards

Other approvals and standards

Other approvals and standards

Protection category acc. to

IEC 529 / EN 60529

Standard: IP 66/67 (NEMA 4/4X/6)

Option: IP 68 (NEMA 6P)

Vibration resistance

IEC 68-2-6

Random vibration test

IEC 68-2-34

Shock test

IEC 68-2-27