TECHNICAL DATA

7

33

TIDALFLUX 4300 F

www.krohne.com

06/2010 - 4000970001 - TIDALFLUX 4300 F R01 en

Installation condtitions

Installation

For detailed information see chapter "Installation"

Flow direction

Forward and reverse.

Arrow on flow sensor indicates positive flow direction.

Inlet run

≥ 5 DN (without disturbing flow, after a single 90° bend)
≥ 10 DN (after a double bend 2x 90°)
≥ 10 DN (behind a control valve)

Outlet run

≥ 3 DN

Dimensions and weights

For detailed information see chapter "Dimensions and weights".

Materials

Sensor housing

Standard: sheet steel

Other materials on request

Measuring tube

Austenitic stainless steel

Flange

Standard: Carbon steel, polyurethane coated

Other materials on request

Liner

Polyurethane

Connection box

IP 67: polyurethane coated die-cast aluminium

IP 68: Stainless steel

Measuring electrodes

Hastelloy

®

C

Grounding rings

Stainless steel

Tailor made to innerdiameter of connecting pipeline.

Necessary if innerside of connecting pipeline isn't electrically

conductive.

Process connections

Flange

Flange

Flange

Flange

EN 1092-1

DN200...1600 in PN 6...40 (others on request)

ASME

8...64" in 150...300 lb RF (others on request)

JIS

DN200...1600 in JIS 10...20 K (others on request)

Design of gasket surface

RF (others on request)