Operation, 2 list of alarm messages – KROHNE PipePatro EN User Manual
Page 41
OPERATION
3
41
PIPEPATROL
www.krohne.com
02/2013 - 4002275001 - MA PipePatrol R01 en
3.7.2 List of alarm messages
Message
Priority
Description
State E-RTTM Signature-
Test: Alarm
2
The E-RTTM module Signature-Test detects a leak.
State E-RTTM
Differential-Test: Alarm
2
The E-RTTM module Differential-Test detects a leak.
State Mass Balance
Differential-Test: Alarm
2
The Mass Balance module Differential-Test detects a leak.
State Shut-In Signature-
Test: Alarm
2
The Shut-In module Signature-Test detects a leak.
Shut-In Inlet: Alarm
Pressure Rising
2
The Shut-In module Signature-Test detects a leak and indicates that the
inlet transmitter shows a positive pressure wave.
Shut-In Inlet: Alarm
Pressure Drop
2
The Shut-In module Signature-Test detects a leak and indicates that the
inlet transmitter shows a negative pressure wave.
Shut-In Outlet: Alarm
Pressure Rising
2
The Shut-In module Signature-Test detects a leak and indicates that the
outlet transmitter shows a positive pressure wave.
Shut-In Outlet: Alarm
Pressure Drop
2
The Shut-In module Signature-Test detects a leak and indicates that the
outlet transmitter shows a negative pressure wave.
Leak Detection System:
Application Alarm
2
The system stopped working due to an internal error.
Alarm LDS-Watchdog
2
A failure of the leak detection system. The Leak Detection software is not
working correctly.