Operation – KROHNE PipePatro EN User Manual
Page 25
OPERATION
3
25
PIPEPATROL
www.krohne.com
02/2013 - 4002275001 - MA PipePatrol R01 en
Sensitivity
Sensitivity
Sensitivity
Sensitivity
The actual sensitivity level of the module under current conditions. The Shut-In module is
showing on the one hand the overall sensitivity of the module, on the other hand it shows the
sensitivity of each monitored pressure transmitter (which can show different sensitivity states).
The following information can be shown:
• Undefined:
Undefined:
Undefined:
Undefined: The module is not running.
• No Sensitivity:
No Sensitivity:
No Sensitivity:
No Sensitivity: No sensitivity available.
• Lowest Sensitivity
Lowest Sensitivity
Lowest Sensitivity
Lowest Sensitivity
• Low Sensitivity
Low Sensitivity
Low Sensitivity
Low Sensitivity
• High Sensitivity
High Sensitivity
High Sensitivity
High Sensitivity
• Highest Sensitivity:
Highest Sensitivity:
Highest Sensitivity:
Highest Sensitivity: The module is offering the highest available sensitivity.
• Mixed Sensitivity:
Mixed Sensitivity:
Mixed Sensitivity:
Mixed Sensitivity: For the Shut-In module only. The sensitivities of the monitored pressure
transmitters are showing different sensitivity states.
Running Leak Rate/Running Pressure Drop
Running Leak Rate/Running Pressure Drop
Running Leak Rate/Running Pressure Drop
Running Leak Rate/Running Pressure Drop
For the Signature-Test and Differential-Test of the E-RTTM module, as well as for the Mass
Balance module, it shows the average value of the estimated leak rate in volume or mass flow.
For the Shut-In conditions it shows the average value of the estimated pressure drops.
Pos. and neg. Leak Threshold under current conditions
Pos. and neg. Leak Threshold under current conditions
Pos. and neg. Leak Threshold under current conditions
Pos. and neg. Leak Threshold under current conditions
For the Signature-Test and Differential-Test of the E-RTTM module, as well as for the Mass
Balance module, it shows the smallest detectable leak rate. For the Shut-In conditions it shows
the smallest detectable pressure drop.
INFORMATION!
•
In case of an alarm it shows the leak rate and leak location.
•
The provided information of each module are also available as trending view by selecting the
trend button (4) of each module.