7.7 RTD and T/C accuracy table
Accuracies in °C
Accuracies in °F
INFORMATION!
•
Conformance level 95% (2σ)
•
CJC = Cold Junction Compensation
Input type
Temp. range
Min. span
Accuracy
Temp. influence
(Dev. from ref. temp. 20°C)
[°C]
[°C]
[°C]
RTD Pt100
-200...+1000
10
±
0.2°C or ±0.1% of span
±
0.01% of span per °C
RTD Ni100
-60...+250
10
±
0.2°C or ±0.1% of span
±
0.01% of span per °C
T/C type J
-200...+1000
50
±
0.3°C or ±0.1% of span
1
±
0.01% of span per °C
T/C type K
-200...+1350
50
±
0.5°C or ±0.1% of span
1
±
0.01% of span per °C
T/C type S
-50...+1750
300
±
2.0°C or ±0.1% of span
1
±
0.01% of span per °C
T/C type B
+400...+1800
700
±
2.0°C or ±0.1% of span
1
±
0.01% of span per °C
1 CJC error is not included
Input type
Temp. range
Min. span
Accuracy
Temp. influence
(Dev. from ref. temp. 68°F)
[°F]
[°F]
[°F]
RTD Pt100
-328...+1832
50
±
0.4°F or ±0.1% of span
±
0.006% of span per °C
RTD Ni100
-76...+482
50
±
0.4°F or ±0.1% of span
±
0.006% of span per °C
T/C type J
-328...+1832
122
±
0.5°F or ±0.1% of span
1
±
0.006% of span per °C
T/C type K
-328...+2462
122
±
0.9°F or ±0.1% of span
1
±
0.006% of span per °C
T/C type S
-58...+3182
572
±
3.6°F or ±0.1% of span
1
±
0.006% of span per °C
T/C type B
+752...+3272
1292
±
3.6°F or ±0.1% of span
1
±
0.006% of span per °C
1 CJC error is not included