beautypg.com

Technical data – KROHNE OPTITEMP TT 50 C-R EN User Manual

Page 31

background image

TECHNICAL DATA

7

31

OPTITEMP TT 50 C/R

www.krohne.com

09/2010 - 4000636502 - MA OPTITEMP TT 50 C/R R03 en

Cold Junction Compensation (CJC)

In-head transmitter:

In-head transmitter:

In-head transmitter:

In-head transmitter:

Celsius: ±0.5°C within ambient temperature -40...+85°C

Fahrenheit: ±0.9°F within ambient temperature -40...+185°F

Rail-mount transmitter:

Rail-mount transmitter:

Rail-mount transmitter:

Rail-mount transmitter:

Celsius: ±0.5°C within ambient temperature -20...+70°C

Fahrenheit: ±0.9°F within ambient temperature -4...+158°F

Temperature influence CJC

±

0.02°C per °C / ±0.02°F per °F

Sensor wire influence

RTD and resistance, 2-wire: adjustable wire resistance compensation.

RTD and resistance, 3-wire: negligible, with equal wire resistance.

RTD and resistance, 4-wire: negligible.

Thermocouple and voltage: negligible.

Supply voltage influence

Negligible

Long-term drift

±

0.1% of span per year

Operating conditions

Temperature

Temperature

Temperature

Temperature

In-head transmitter

Operating and storage temperature:

Operating and storage temperature:

Operating and storage temperature:

Operating and storage temperature:

Standard version: -40...+85°C / -40...+185°F

Intrinsically safe version: for detailed information refer to

Temperature data

for potentially explosive areas on page 37.

Rail-mount transmitter

Storage temperature:

Storage temperature:

Storage temperature:

Storage temperature:

-40...+85°C / -40...+185°F

Operating temperature:

Operating temperature:

Operating temperature:

Operating temperature:

-20...+70°C / -4...+158°F

Humidity

5...95% RH (non-condensing)

Protection category

Protection category

Protection category

Protection category

In-head transmitter

Housing: IP50

Terminals: IP10

Rail-mount transmitter

Housing: IP20

Terminals: IP00

Installation conditions

Mounting

In-head transmitter: DIN B-head or larger, DIN-rail (with adapter).

Rail-mount transmitter: rail acc. to DIN 50022 / EN 60715, 35 mm / 1.38".

For detailed information refer to chapter "Installation".

Weight

In-head transmitter: 50 g / 0.11 lb

Rail-mount transmitter: 70 g / 0.15 lb

Dimensions

For detailed information refer to

Dimensions on page 34.

.book Page 31 Monday, September 13, 2010 5:07 PM