TECHNICAL DATA

7

37

OPTITEMP TT 50 C/R

www.krohne.com

09/2010 - 4000636502 - MA OPTITEMP TT 50 C/R R03 en

Formula for the maximum permissible output load of the TT 50 R:
permissible R

Load

[Ω] = (U-11)/0.023

7.5 Temperature data for potentially explosive areas

In-head transmitter (Ex-version)

7.6 Electrical data for outputs and inputs

In-head transmitter (Ex-version)

Output load diagram TT 50 R

1 R: total output load in Ω
2 U: supply voltage in VDC

Temperature class

Ambient temperature T

a

T6

-40°C ≤ T

a

≤ +50°C / -40°F ≤ T

a

≤ +122°F

T5

-40°C ≤ T

a

≤ +65°C / -40°F ≤ T

a

≤ +149°F

T4

-40°C ≤ T

a

≤ +85°C / -40°F ≤ T

a

≤ +185°F

Ouput (supply)

Input (sensor)

Max. voltage to

transmitter

U

i

= 30 VDC

Max. voltage from

transmitter

U

o

= 30 VDC

Max. current to

transmitter

I

i

= 100 mA

Max. current from

transmitter

I

o

= 25 mA

Max. power to

transmitter

P

i

= 900 mW

Max. power from

transmitter

P

o

= 190 mW

Internal inductance

L

i

= 1 mH

Max. inductance (input

loop)

L

o

= 19 mH

Internal capacitance

C

i

= 1 nF

Max. capacitance (input

loop)

C

o

= 31 nF

.book Page 37 Monday, September 13, 2010 5:07 PM