INSTALLATION

2

11

OPTIFLEX 2200 C/F

www.krohne.com

08/2013 - 4000622103 - QS OPTIFLEX 2200 R03 en

For single cable and single rod probes:

Figure 2-10: Recommended nozzle dimensions for single rod and single cable probes

1 Recommended conditions: h ≤ d, where h is the height of the tank nozzle and d is the diameter of the tank nozzle.
2 The end of the nozzle must not have an extension into the tank. Do not install the device on a high nozzle.

CAUTION!
If the device is installed on a high nozzle, make sure that the probe does not touch the side of the
nozzle (attach the probe end, ...).

Figure 2-11: Sockets for threaded process connections

1 Recommended installation
2 The end of the socket must not have an extension into the tank