beautypg.com

GW Instek GPT-800 Series User Manual

Page 9

background image

ELECTRICAL SAFETY TESTER

USER MANUAL

11

4-1. Front Panel

1

Model Number

Model number and description

2.

Display

Indicate all messages about test procedure.

3.

CAUTION
Indicator LED

During test the red LED will flash to indicate
dangerous.

4.

START Button

Press the green button to start a test procedure.

5.

RESET Button

Press the red button to reset/stop a test procedure.

6.

ARC VR

Control ARC range.

7.

Current VR

Control the range of Cut-off current.

8.

I Set/ARC Set

: I Set, : ARC Set

9.

ARC Con./Stop

: A signal for stop test. when the ARC is in use,

the test will be stopped.

: A signal for continuous test.

10. Range

Switch over the range.

11. Time VR

Control test time.

12. TIMER ON/OFF

: Power on and the test time can be adjusted.
: Power off and the test time can not be adjusted.

13. Test Voltage

Test voltage adjustment.

14. Setting (Current,

ARC, & Test)

: Can adjust Current/ARC VR to set current and

ARC.

: Stand by status for testing.

15. AC/DC or AC/IR

: AC withstand voltage test.
: DC withstand voltage test (only for GPT-815)

or Insulation Test (only for GPI-825/826).

16. 500V/1000V

: 500V, : 1000V(for GPI-825/826 only)

17. High Voltage Output

Seat

High voltage output terminal

18. RETURN terminal

The test return terminal.

19. Power switch

Power on to start test.

ELECTRICAL SAFETY TESTER

USER MANUAL

12

4-2. Rear Panel

20. Fuse Holder with

Voltage Selector

To change AC source voltage, pull the fuse holder and
replace with an adequate fuse to connect with AC
power cord.

21. Ground Terminal

Connect Ground terminal to the earth ground.

22. Remote I/O Control Remote I/O output joint point:

Test signal: Two test holes has to be shorted when

getting into test mode by pressing Start
key, and it won’t return to open status
until the test result of PASS or FAIL
comes available, or the RESET key is
pressed.

PASS signal: At the time when the test result comes

out to be PASS, two PASS holes has to
be shorted, and return to open until the
RESET key is pressed.

FAIL signal: At the time when the test result comes

out to be FAIL, two FAIL holes has to
be shorted, and return to open until the
RESET key is pressed.

RESET: The function is same as the RESET key on

the front panel.

START: The function is same as the START key on

the front panel.

23. Current Monitor

The cutoff current can be directly monitored by
disconnecting the shorting bar from these terminals
and connecting a milliammeter (DC/AC) between
them. The milliammeter should be capable of
measuring the cutoff current. Be sure to connect the
shorting bar when no milliammeter is connected
between these terminals.

This manual is related to the following products: