GW Instek GPT-800 Series User Manual
Page 9
ELECTRICAL SAFETY TESTER
USER MANUAL
11
4-1. Front Panel
1
Model Number
Model number and description
2.
Display
Indicate all messages about test procedure.
3.
CAUTION
Indicator LED
During test the red LED will flash to indicate
dangerous.
4.
START Button
Press the green button to start a test procedure.
5.
RESET Button
Press the red button to reset/stop a test procedure.
6.
ARC VR
Control ARC range.
7.
Current VR
Control the range of Cut-off current.
8.
I Set/ARC Set
: I Set, : ARC Set
9.
ARC Con./Stop
: A signal for stop test. when the ARC is in use,
the test will be stopped.
: A signal for continuous test.
10. Range
Switch over the range.
11. Time VR
Control test time.
12. TIMER ON/OFF
: Power on and the test time can be adjusted.
: Power off and the test time can not be adjusted.
13. Test Voltage
Test voltage adjustment.
14. Setting (Current,
ARC, & Test)
: Can adjust Current/ARC VR to set current and
ARC.
: Stand by status for testing.
15. AC/DC or AC/IR
: AC withstand voltage test.
: DC withstand voltage test (only for GPT-815)
or Insulation Test (only for GPI-825/826).
16. 500V/1000V
: 500V, : 1000V(for GPI-825/826 only)
17. High Voltage Output
Seat
High voltage output terminal
18. RETURN terminal
The test return terminal.
19. Power switch
Power on to start test.
ELECTRICAL SAFETY TESTER
USER MANUAL
12
4-2. Rear Panel
20. Fuse Holder with
Voltage Selector
To change AC source voltage, pull the fuse holder and
replace with an adequate fuse to connect with AC
power cord.
21. Ground Terminal
Connect Ground terminal to the earth ground.
22. Remote I/O Control Remote I/O output joint point:
Test signal: Two test holes has to be shorted when
getting into test mode by pressing Start
key, and it won’t return to open status
until the test result of PASS or FAIL
comes available, or the RESET key is
pressed.
PASS signal: At the time when the test result comes
out to be PASS, two PASS holes has to
be shorted, and return to open until the
RESET key is pressed.
FAIL signal: At the time when the test result comes
out to be FAIL, two FAIL holes has to
be shorted, and return to open until the
RESET key is pressed.
RESET: The function is same as the RESET key on
the front panel.
START: The function is same as the START key on
the front panel.
23. Current Monitor
The cutoff current can be directly monitored by
disconnecting the shorting bar from these terminals
and connecting a milliammeter (DC/AC) between
them. The milliammeter should be capable of
measuring the cutoff current. Be sure to connect the
shorting bar when no milliammeter is connected
between these terminals.