beautypg.com

GW Instek GPT-800 Series User Manual

Page 6

background image

ELECTRICAL SAFETY TESTER

USER MANUAL

5

Warning: Unlike power supply which can be used on the

extreme low load range, when the series are used on the AC

voltage, the suggestive load should be more than 500VA at
50k
Ω and 100VA at 250kΩ, while used on the DC voltage,

more than 500kΩ load is suggested.

5) ARC Detect

500VA : 0.3~100mA

Detect Current

100VA : 0.3~20mA

6) Interface

Terminal type

Terminal seat

7) General Specification

Power Source

AC115V/ 230V±10%, 50/60Hz

Operation
Environment

Indoor use, altitude up to 2000m.

Relative Humidity 80% (Maximum).

Installation category II
Pollution Degree 2

Operation Temperature &
Humidity

0℃ ~ 40℃, <70%

Storage temperature &
Humidity

-10℃ ~ 70℃, <70%

Accessories

Power cord × 1,
Test lead (GHT-105A) × 1,
Instruction manual × 1

Dimension

446(L) × 330(W) × 149(H) (m/m)
GPT/GPI-8X5: 20kgs, GPI-826: 13kgs approx.

* All specifications are guaranteed under the distortion of AC power

source less than 3%.

ELECTRICAL SAFETY TESTER

USER MANUAL

6

3. PRECAUTIONS BEFORE OPERATION

3-1. Unpacking the instrument

The product has been fully inspected and tested before shipping

from the factory. Upon receiving the instrument, please unpack and

inspect it to check if there is any damage caused during

transportation. If any sign of damage is found, notify the bearer

and/or the dealer immediately.

3-2. Checking the Line Voltage

The instruments can be applied with any kind of line voltage shown

in the table below. Before connecting the power plug to an AC line

outlet, make sure the voltage selector of the rear panel is set to the

correct position corresponding to the line voltage. It might be

damaged the instrument if connected to the wrong AC line voltage.

WARNING: To avoid electrical shock the power

cord protective grounding conductor must be

connected to ground.

The equipment shall not be used for

measurements within category II, III and IV.

When line voltages are changed, replace the required fuses shown as

below:

Line voltage

Range

Fuse

Line voltage

Range

Fuse

115V

105-125V

T 6.3A

250V

230V

207-250V

T 3.15A

250V