GW Instek GFG-8210A User Manual
Page 10
FUNCTION GENERATOR
USER MANUAL
17
14a
5-6.Variation of external voltage-controlled frequency
This mode of operation allows the user to adjust the frequency of the
function generator with an external DC control Voltage. It also provides
an easy way for your adjustment.
(1) Select Function
8
first, then select Range
7
, rotate FREQ
13
to set required frequency range.
(2) Connect external control voltage (0~10V) to the VCF
connector via a suitable lead, and generate signal from Output
.
(3) Other adjustments, such as AMPL
12
switch can change
amplitude of signal, or get attenuation; adjust Offset
11
for DC
level, rotate Duty k switch can change output signal of pulse or
ramp waveform etc..
5-7.Auto Sweep
(1) First select the required waveform by pressing Function
8
button,
then select required frequency range by pressing range
7
push
button.
(2) Connect output terminal
to oscilloscope for observing output
signal.
(3) Rotate frequency
13
to determine the upper limit frequency.
(4) Pull out frequency
13
to perform auto-sweep operation.
(5) Rotate SWEEP/TIME
14
and SWEEP/RATE to adjust
sweep time and rate.
(6) Pull out (press) LIN/LOG
14
to obtain LOG (LIN) sweep mode.
Note: The sweep width can only be adjusted during the sweep cycle
and it can not be stopped.
FUNCTION GENERATOR
USER MANUAL
18
5-8. Precaution item
(1) Adjust DC OFFSET, will provide to change voltage of ±10V (no
load) or ±5V (50Ω load). However, signal added DC level, is
still limited to ±20V (no load) or ± 10V (50Ω load). In case of
over-voltage, clip will appear as shown in Figure 2:
(2) Output connector label 50 Ω , indicated that signal source
impedance is 50Ω. Connect to any of impedance circuit, but
output voltage and terminal impedance will be rated. To avoid
oscillation, terminal shall be connected to 50Ω (When using high
frequency and square output), and its connecting line shall be as
short as possible.
(3) When adjust Duty knob to leftward position, the ratio of positive
state to negative state, expand to not less than 80:20. It can expand
Square wave to Pulse wave, expand Triangle wave to Ramp wave
and Sine wave to unsymmetrical Sine wave. As shown in Figure 3
is for adjustment of Duty control to obtain required waveform.