5.1) Testing of Pump (Main Switch)
1)

With the discharge line in place, plug in the pump.

2)

Pour water into the pump reservoir, through one of the inlets, until the pump activates to verify that the unit

works.

Note:

If both inlets are plumbed, then it will be necessary to temporarily remove one of the pipes in order to pour water

into the reservoir. Replace pipe once testing is complete.

5.2) Testing of Safety Switch (If applicable)

Note:

Unplug the pump for this test.

1)

Energize the appliance so that it runs.

2)

Pour water into the reservoir as described in Section 5.1 item 2.

3)

As water rises in the reservoir, the overflow Switch should activate, breaking the thermostat circuit to the appli-

ance and/or triggering the alarm.

4)

Plug the pump in and allow the pump to empty the tank. As the water level decreases, the appliance will reset.

Trouble Shooting Guide

A. UNIT DOESN’T RUN.

B. PUMP MAKES LOUD NOISES WHEN

RUNNING.

C. PUMP RUNS BUT DOES NOT PUMP

LIQUID OUT.

D. LIQUID DRAINS BACK INTO PUMP

FROM DISCHARGE LINE.

E LIQUID LEAKS FROM AROUND

CHECK VALVE.

Pump not plugged in.

Low voltage; blown fuse, open circuit.

No condensate in reservoir.

Motor or wiring shorted.

Drain/Discharge line(s) blocked.

Debris in reservoir.

Float bound.

Maximum discharge height exceeded.

Discharge tube blocked.

Check Valve obstruction.

Check Valve damaged.

Check Valve damaged.

Check Valve obstruction.

Highest point of discharge line is less

than 5’.

Check Valve is too tight or too loose.

O-ring damaged.

Plug in.

Have a qualified electrician check fuse circuit.

Be certain the appliance is generating con-

densate. Check drain line(s) and/or discharge

line for blockage.

Contact Factory.

Check drain line(s) and/or discharge line for

blockage.

Refer to “Maintenance Guidelines” section for

cleaning instructions.

Refer to “Maintenance” section for cleaning

instructions.

Measure from bottom of pump to highest point.

Rework discharge if height is greater that 18’.

Refer to STEP 3 for guidelines.

Check discharge line for blockage, remove

debris.

Refer to “Maintenance” section for cleaning

instructions.

Contact Factory.

Contact Factory.

Refer to “Maintenance” section for cleaning

instructions.

Check valve may allow some condensate to

drain out of line into reservoir. This is normal.

Check valve should be hand tight, then tighten

an additional 1/2 turn with a 9/16” wrench.

Replace with a 1/2 ID X 11/16” OD X 3/32” thick

O-ring or contact Star Service Station.

Condition

Possible Cause

Remedy

Before servicing a pump, always shut off the main power

breaker and then unplug the pump - making sure you are not standing in

water and are wearing insulated, protective-sole shoes. Under flooded condi-

tions, contact your local electric company or a qualified licensed electrician

for disconnecting electrical service prior to pump removal.

If the above checklist does not solve the problem, consult Star Water Systems

Technical Service Department 1-800-345-9422 - Do not attempt to service or

otherwise disassemble pump.

STEP 5

Testing of Pump Operation