Spectra Precision Survey Pro v5.1 User Manual
Page 30
24
Start the station setup as follows:
•
Go to the Main Menu, then tap
Survey > Station Setup.
•
Choose
Setup Type= Known Point.
•
Enter the name of the station setup point in the
Occupy Point field. The
point name can be entered directly, or, picked from the map or point list
using the
button.
•
If you wish to ignore elevations in your job, check the
2D Survey box. You
will otherwise enter the
HI (height of instrument) field.
•
Tap
Next.
Then, of the three possible options, choose the one that is suitable for your job:
1. If you choose
BS Azimuth:
• Aim the instrument in the direction of a known or assumed azimuth.
• Enter the known or assumed value of azimuth.
• Enter the desired value of circle in this direction (typically “0” or the
true azimuth). If the
Survey with True Azimuths setting is enabled, then
the circle value will automatically be set by Survey Pro.
• Tap
Set Circle.
• Tap
Next. The screen provides a summary of what you have just done and
prompts you to check the setup.
Check the Setup:
a. If you choose the
By Angle option, just make sure the instrument is
still aimed in the direction of known azimuth, then tap
Check. You
should read the previously set backsight circle.
b. If you choose the
By Point option, enter the name of the point used
for checking, specify the target used on that point, correct the target
height if necessary and tap
Check. A measurement is then made. Check
the delta values reported on the screen, which should be as close as
possible to zero.
c. You cannot use the
By Distance option in this case.
• If you are satisfied with the read values, tap
Finish. You can now start
measuring new points.
NOTE: Checking the backsight is an optional step that is enabled by default. If
you wish to skip backsight checks after station setup, you can turn this off in
the
Job > Settings > Surveying tab.