2 troubleshooting sct, Toolbars – Seed Hawk TOOLBAR 2015 User Manual
Page 56
![background image](/manuals/364496/56/background.png)
SEED HAWK
®
2015 TOOLBAR OPERATOR’S MANUAL 51
7.2 Troubleshooting SCT
®
Toolbars
Gates will not open/close
Openers will not lift
Random opener sections lifting
Wing down switch will not work
Probable Cause
Solution
No hydraulic pressure to
meter block.
Engage hydraulic circuit (wing down).
Check SCT
®
node
Check lights on front of node
Meter block PRV (pressure
relief valve) set too low.
Increase PRV pressure until gates cycle (do not
exceed 500 psi).
No power at coils.
Turn master switch on.
Check fuses.
Check connections at coil and SCT
®
node.
Probable Cause
Solution
No hydraulic pressure to
meter block.
Engage hydraulic circuit (opener).
Meter block PRV (pressure
relief valve) set too low.
Increase pressure (factory set to 2200 psi).
No power at coils.
Turn master switch on.
Check fuses.
Check connections at coil and SCT
®
node.
Probable Cause
Solution
Improper look aheads.
Ensure that the look ahead number is not a neg-
ative number.
Agressiveness set too high. Turn aggressiveness off.
Improper drill setup.
Check drill setup.
Probable Cause
Solution
No hydraulic pressure.
Engage hydraulic circuit (wing down).
Master switch on.
Turn master switch off (unfold only).