1.
Ratings and Specifications
The RS 400 door provides manual or automatic operation of rollup fabric for industrial installations. The RS
400 doors are intended for moderate exposure and moderate wind conditions. Framing dimensions of the
RS400 doors are shown in the following diagram and tables.
TABLE 1 RS 400Door Framing Dimensions:
Width Related Dimensions
Height Related Dimensions
RS-400
A
RS-400
B
Width (Ft.)
Ft.
In.
cm
Height(Ft.)
Ft. In. cm
10' 11
1-3/4
340
8'
9 6
290
11' 12
1-3/4
370
9'
10 6
320
12' 13
1-3/4
401
10'
11 6
351
13' 14
1-3/4
431
11'
12 6
381
14' 15
1-3/4
462
12'
13 6
411
15' 16
1-3/4
492
14'
15 6
472
16' 17
1-3/4
523
15'
16 6
501
17' 18
1-3/4
553
16'
17 6
533
18' 19
1-3/4
584
19' 20
1-3/4
614
20' 21
1-3/4
645
Diagram 1 – Door Dimensions and Clearances
6.85
(17.4cm)
Height
B
A
Width
18"
(45.7 cm)
12 1/2"
(31.75 cm)
3 11/16"
(9.36 cm)
- Polar Cool: Portable Evaporative Cooling System (22 pages)
- Polar Cool: External Control Box (4 pages)
- Polar Cool: Pump & Float Replacement (2 pages)
- Polar Cool: PUMP REPLACEMENT (4 pages)
- Polar Cool: Wall Mount Kit (4 pages)
- Unitized Mega Cool (68 pages)
- Unitized Mega Cool: Square Bottom (63 pages)
- Mega-Cool: Square Reservoir (24 pages)
- Mega-Cool rev 6-09 (46 pages)
- Mega-Cool: Mega-Cool Pad Extender Kit (5 pages)
- Mega-Cool: Float Valve Replacement (1 page)
- Mega-Cool: Float Valve (Topaz) Replacement (1 page)
- Mega-Cool: In-Line Pump Motor Replacement (2 pages)
- Var-O-Matic (2 pages)
- System 1000 Power Vent (31 pages)
- System 1000 Power Vent (13 pages)
- System 500 Programs (Conventional Model) (5 pages)
- System 100 Variable Speed Controller (7 pages)
- System 500 Programs (Tunnel Model) (7 pages)
- System 1000 Power Curtain (17 pages)
- System 2000 AUTO TEMP (10 pages)
- System 2001 Power Curtain Controller (43 pages)
- System 500 Power Curtain Controller (31 pages)
- System 1000 Power Curtain Eight Stage Controller (34 pages)
- ICS-500 Environmental Controller (34 pages)
- Pressure Transducer Changeout (1 page)
- HH Software: HH.Net Router/Repeater (8 pages)
- HH Software: 900SS Wireless Network (10 pages)
- HH Software: Farm Manager (22 pages)
- HH Software: Data Shuttle Launch Pad (25 pages)
- Sens-O-Matic (Feed Hopper Switch) (2 pages)
- Manual Light Dimmer (2 pages)
- Electro Mechanical Controls (Relay-Switches): PHOTOHELIC POWER VENT (10 pages)
- Electro Mechanical Controls (Relay-Switches): PT Controller (9 pages)
- Electro Mechanical Controls (Relay-Switches): PC-DB Curtain Controller with DIF (6 pages)
- Electro Mechanical Controls (Relay-Switches): PC-DB Curtain Controller with Timer Override (7 pages)
- Electro Mechanical Controls (Relay-Switches): Photohelic Gauge (1 page)
- Feed Management System (15 pages)
- Contactor Control System (CCS): 4, 8, or 12 Stage (19 pages)
- Contactor Control System (CCS): Triple Pole 16-Stage (7 pages)
- Contactor Control System (CCS): Vent Machine Override 3 Wire PowerTrak (1 page)
- Evolution 4000 Control System (86 pages)
- Evolution Series 1200: Variable Output With Override Pot (14 pages)
- Evolution Series 1200: Variable Output (12 pages)
- Evolution Series 1200 (64 pages)