6.1.2.1.3.Alternate Program Switch

PROGRAM

(Programa)

A

B


Each of the 256 stage programs has another “shadow” program. This
separate program is provided to make the change between brooding
and full house operation. Position A is a program tailored for
brooding, whereas program B is for full house operation.

6.1.2.1.4.Target Temperature

TARGET TEMPERATURE

(Temperatura Optima)

INCREASE

DECREASE

(Disminuir)

(Aumentar)


The target temperature knob is used for the adjustment of target
temperature. This setting is very important, because all system
operations other than the timer are operated by the distance between
target temperature and actual temperature. At all times, the system
will try to maintain target temperature.

6.1.2.1.5.Timer Percentage

TIMER PERCENTAGE

(Reloj De Ventilacion Minima)

TIMER

INCREASE

DECREASE

(Disminuir)

(Aumentar)


This control allows the operator to specify the amount of time a stage
on the timer stays energized. For example:
10 Minute timer with Timer Percentage at 40%
The stage will be active for 40% of 10 min.--4 min.
The timer percentage control works in the same manner for a 5 minute
timer.
On this display, the word "Timer" will be backlit red if the stages on
the timer are active.