Suspended ceiling T-Bar mount instructions
2
14
Brocade Mobility 1240 Access Point Installation Guide
53-1002917-01
Suspended ceiling T-Bar mount instructions
Ceiling mount requires holding the Mobility 1240 Access Point up against a T-bar of
a suspended ceiling grid and twisting the unit on to the T-bar. If deploying the
Mobility 1240 Access Point on a sculpted ceiling T-Bar, the access point mounting
kit (Part No. KT-135628-01) can optionally be used as well.
1. If required, install and attach a Kensington security cable (customer provided)
to the unit’s lock port.
2. Using only the mounting bracket from the mounting kit, rotate and click the
mounting bracket into the mounting slots on the Mobility 1240 Access Point.
3. Attach the antennas to their correct connectors. For more information on
supported Mobility 1240 Access Point antennas, see
Point antenna options” on page 20
.
4. Cable the access point using either power over Ethernet or the approved
Mobility 1240 Access Point power supply (PWRS-14000-247R).
For power over Ethernet installations:
a. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the power over
Ethernet switch port and the access point’s GE1/POE port.
b. Ensure the cable length from the Ethernet source (host) to the power over
Ethernet and access point does not exceed 100 meters (333 ft).
For standard power adapter (non power over Ethernet) and line cord
installations:
a. Connect a RJ-45 Ethernet cable between the network data supply (host)
and the access point’s GE1/POE or GE2 port.
b. Verify the power adapter is correctly rated according to the country of
operation.
c. Connect the power supply line cord to the power adapter.
d. Attach the power adapter cable into the power connector on the access
point.
e. Attach the power supply line cord to a power supply.