Mechanical Forces
-
Allowed Loads on Bumper Rear Points S1: theoretical pressure/tensile force values confirmed
with destruction tests
-
Applied Loads on Bumper Rear Points S1: configuration applied value (turns red if outside
limits)
-
Allowed Loads on Bumper Front Points S2: theoretical pressure/tensile values confirmed with
destruction tests
-
Applied Loads on Bumper Front Points S2: configuration applied value (turns red if outside
limits)
-
Allowed Moment on Extension Bar (closed cross-section): theoretical maximum moment force
before bending, confirmed with destruction tests
-
Applied Moment on Extension Bar (closed cross-section): configuration applied value (turns red
outside above limits)
-
Allowed Moment on Link Bar: theoretical maximum moment force before bending, confirmed
with destruction tests
-
Applied Moment on Link Bar: configuration applied value (turns red if outside limits)
-
Allowed Load on CD12 flying rails: theoretical tensile force values
-
Applied Load on CD12 flying rails: configuration applied values (turns red if outside limits)
-
Wind force applied on cluster:
Rear or Front force applied when wind is present (Beaufort Scale = 8)
-
Wind Offset Angle: Vertical Cluster rotation related to wind forces
Angle Sequence
-
Delta: Inter Cabinets Angle Sequence
-
Sum: Cumulative Angle Sequence (which takes wind effect into account)