Mechanical Forces

-

Allowed Loads on Bumper Rear Points S1: theoretical pressure/tensile force values confirmed
with destruction tests

-

Applied Loads on Bumper Rear Points S1: configuration applied value (turns red if outside
limits)

-

Allowed Loads on Bumper Front Points S2: theoretical pressure/tensile values confirmed with
destruction tests

-

Applied Loads on Bumper Front Points S2: configuration applied value (turns red if outside
limits)

-

Allowed Moment on Extension Bar (closed cross-section): theoretical maximum moment force
before bending, confirmed with destruction tests

-

Applied Moment on Extension Bar (closed cross-section): configuration applied value (turns red
outside above limits)

-

Allowed Moment on Link Bar: theoretical maximum moment force before bending, confirmed
with destruction tests

-

Applied Moment on Link Bar: configuration applied value (turns red if outside limits)

-

Allowed Load on CD12 flying rails: theoretical tensile force values

-

Applied Load on CD12 flying rails: configuration applied values (turns red if outside limits)

-

Wind force applied on cluster:

Rear or Front force applied when wind is present (Beaufort Scale = 8)

-

Wind Offset Angle: Vertical Cluster rotation related to wind forces

Angle Sequence

-

Delta: Inter Cabinets Angle Sequence

-

Sum: Cumulative Angle Sequence (which takes wind effect into account)