18/38
Rig Angles Tab
Vertical Angle Configuration
Horizontal Dispersion Configuration
Choices between the cabinets are :
GEO S8
-
S805 to S805 : 0.31 - 0.50 - 0.80 – 1.25 – 2.00 – 3.15 – 5.00 degrees ;
-
S805 to S830 : 17.5 degrees ;
-
S830 to S830 : 17.5 -30 degrees ;
GEO S12
-
S1210 to S1210:
0.20 - 0.31 - 0.50 - 0.80 – 1.25 – 2.00 – 3.15 – 5.00 – 6.25 – 8.00 – 10 degrees ;
-
S1210 to S1230: 16 degrees;
-
S1230 to S1230: (16) - 22.5 – 30 degrees;
NB: 16° is allowed for specific installations where high dBSPL values are required.
However, bandwidth is then limited to 10 kHz.
GEO D
-
D10 to D10 (or D10 to GEO SUB or GEO SUB to GEO SUB)
0.20 - 0.31 - 0.50 - 0.80 – 1.25 – 2.00 – 3.15 – 5.00 – 6.25 – 8.00 – 10 degrees ;
GEO T
-
T4805 to T4805 : 0.12 – 0.20 - 0.31 - 0.50 - 0.80 – 1.25 – 2.00 – 3.15 – 5.00 degrees ;
-
T4805 to T2815 : 6.30 - 8.00 –10.00 degrees ;
-
T2815 to T2815 : 6.30 - 8.00 – 10.0 - 12.5 – 15.0 degrees.
Step
Non editable field ; gives the distance between adjacent cabinets targeted points on the audience.