MENU DESCRIPTION

Pin Name

In/Out

Meaning when set to 0

(Default)

Meaning when set to 1

GPInput 1

In

CH 1 unmuted

CH 1 muted

GPInput 2

In

CH 2 unmuted

CH 2 muted

GPInput 3

In

CH 3 unmuted

CH 3 muted

GPInput 4

In

CH 4 unmuted

CH 4 muted

GPInput 5

In

NXAMP is ON

NXAMP is in Stand-by

GPOutput 1

Out

CH 1 no current out

CH 1 current out

GPOutput 2

Out

CH 2 no current out

CH 2 current out

GPOutput 3

Out

CH 3 no current out

CH 3 current out

GPOutput 4

Out

CH 4 no current out

CH 4 current out

GPOutput 5

Out

CH 1 no clip/protect

CH 1 clip or protect

GPOutput 6

Out

CH 2 no clip/protect

CH 2 clip or protect

GPOutput 7

Out

CH 3 no clip/protect

CH 3 clip or protect

GPOutput 8

Out

CH 4 no clip/protect

CH 4 clip or protect

If GPInput1 is ‘High’, Channel 1 will be muted. If GPInput1 is ‘Low’, Channel 1 will be

unmuted. Front Panel mute/Unmute is still working.

If GPInput2 is ‘High’, Channel 2 will be muted. If GPInput2 is ‘Low’, Channel 2 will be

unmuted. Front Panel mute/Unmute is still working.

If GPInput3 is ‘High’, Channel 3 will be muted. If GPInput3 is ‘Low’, Channel 3 will be

unmuted. Front Panel mute/Unmute is still working.

If GPInput4 is ‘High’, Channel 4 will be muted. If GPInput4 is ‘Low’, Channel 4 will be

unmuted. Front Panel mute/Unmute is still working.

If GPInput5 is ‘High’, Amplifier will go to Stand-by mode. If GPinput5 is ‘Low’, Amplifier will

go back to running mode.

GPOutput1 to 4 reflects the "Signal" LED on the front panel (meaning current flowing on

the output). It will be possible to select a threshold in a next release (a Pilot Tone

generator will be implemented also). The GPOutput5 to 8 reflects the "Protect" OR the

"Peak" signal for each channel.

GPIO mode 2 (Installer mode)

This mode is intended to be used with permanently ‘High’ or ‘Low’ state signals. A state is

validated when the state of the pin has changed and is stable for 1 second. There is an

action depending on the state of each GPI. Here is the detail: