beautypg.com

Nxamp thermal dissipation and current drawn – Nexo NUAR User Manual

Page 127

background image

NXAMP THERMAL DISSIPATION AND CURRENT DRAWN

NXAMP Thermal dissipation and current drawn

Test signal: Pink Noise, bandwidth limited 22Hz to 22 kHz. All channels driven.

Line Current (A)

Thermal

Dissipation

NXAMP4X1

120V 230V

Watts

Dissipated

Btu/h kcal/h

Idle 1.6

0.9

95 326

82

8ohms/ch 11.1

6.1

390 1337

337

4ohms/ch 16.7

9.2

590 2023

510

1/8out

2ohms/ch 21.8

12.0

620 2126

536

Line Current (A)

Thermal

Dissipation

NXAMP4X4

120V 230V

Watts

Dissipated

Btu/h kcal/h

Idle 2.3

1.3

120 411

104

8ohms/ch 26.0

14.3

800 2743

691

4ohms/ch 40.0

22.0

1300 4457

1123

1/8out

2ohms/ch 50.0

27.5

1700 5829

1469

1 BTU = 1,055.06 J = 0.252 kcal

(W)*864=cal

N.B. These values are for NXAMP without NXES104/NXDT104 or NX-DFLT board fitted. If

card is fitted, please add 5 Watts to these values.

PAGE 127 OF 140