STEP 7 COMMISSIONING

WARNINGS:

The motor casing can become very hot under normal operating

conditions, care should be taken to ensure it cannot be touched during

operation.

Do not run pump without guards and terminal box lid correctly fitted.

The pump chamber must be full of water at all times. Seal damage will

result if the pump runs dry.

1. System

Flushing

This pump incorporates push-in connectors and plastic components that

must not come into contact with solder flux, acid-based descalents or

aggressive cleaning agents. The pipework system should be flushed out

prior to the pump being connected to ensure any contaminants/chemical

residues and foreign bodies are removed from elsewhere in the system.

2. Water

Supply

Always ensure that water storage capacity is adequate to meet the demand.

Ensure the pump chamber is full of water before starting the pump. Failure

to do this could result in seal damage. To ensure dry running does not

occur the pump must be primed as described in the priming section.

Do

not run pump dry.

3. Priming

The pump must be primed (filled with water) before starting. Turn on water supply,

prime and vent the pump by unscrewing the priming plug (Figs. 13 & 14) slowly

until all air escapes and water emerges. Re-tighten the plug.

Monsoon Extra 3.2 PS
Fig. 13

Monsoon Extra 4.7 PS
Fig. 14

Priming
Plug

Priming
Plug