Stuart Turner 3.2 bar PS User Manual
Page 11

- 11 -
To enable correct assembly of the cable gland the ‘O’-ring (1) must be placed over the
cable before the clamping insert (2) can be tightened.
Note: Cable diameter range:- 6.5 mm to 9.5 mm.
Supply Cord Replacement
If the supply cord is to be changed or is damaged, it must be replaced with a special cord
assembly available from Stuart Turner or one of their approved repairers.
On disassembly note the cord retention and routing system. Reassemble to the same
pattern.
For information on cable connection consult the wiring diagram and cable gland fitting
instructions.
Intermediate Connecting Cord Replacement
These pumps incorporate an additional cord which connects the main terminal box to
the motor terminal box. If this cord is damaged, it must be replaced with a special cord
assembly available from Stuart Turner or one of their approved repairers.
On disassembly note the cord retention and routing system. Re-assemble to the same
pattern.
For information on cable connection consult the wiring diagram.
Supply Cord Extension
The pumps are fitted with a supply cord to the following specification:-
HO7RN-F3 G 1.0 mm² - 10 Amp rated cable.
If the supply cord is to be extended, a cord of the same specification should be used.
Any connections or junction boxes used should be specifically suited for the application
and installed in accordance with the manufacturers’ instructions.
Cable Gland Fitting Instructions
Cont ...
Fig. 12
1
2