Fuses
The following fuse size should be used with the appropriate pump:
Wiring Of Connection Unit
WARNING: This appliance must be earthed.
The wires in the mains lead are coloured in accordance with the following code:
Green and Yellow: Earth
Blue: Neutral Brown: Live
As the colours of the wires in the mains lead of this appliance may not correspond with
the coloured markings identifying the terminals in your connection unit proceed as follows:
The wire which is coloured green and yellow must be connected to the terminal in the
connection unit which is marked with the letter E or by the earth symbol:
or coloured
green or green and yellow.
The wire which is coloured blue must be connected to the terminal which is marked with
the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked
with the letter L or coloured red.
Wiring Diagram
The supply cord and internal wiring within the terminal box are routed and
secured to ensure compliance with the electrical standard EN 60335-1. It
is essential that any disturbance of this internal wiring is avoided and the
factory routing and securing of all internal wiring is always maintained.
Model
Fuse Size (AMPS)
All Models
13
Cont ...
FLOWSWITCH
REED (S2)
BL
UE
BROWN
GREEN / YELLOW
BLUE
BROWN
L
M
A
N
N
S3 S3
L
E
N
S2
S2
PRESSURE
SWITCH (S1)
GREEN / YELLOW
230 VAC/1PH/50Hz
SUPPLY
BL
AC
K
BL
AC
K
BROWN
WH
ITE
BL
UE
CAPACITOR
MOTOR
S1
S1
Fig. 11