Index – Yokogawa DAQWORX User Manual
Page 38

3-7
IM WX1-07E
Funct
ons
1
2
3
Index
Alarm Type on Devce Sde
Alarm Type after Change
PV
SP
OUT, HOUT, COUT
De-energized on deviation high limit
alarm for target setpoint
Other [ETC]
Deviation high limit [DH]
—
De-energized on deviation low limit
alarm for target setpoint
Other [ETC]
Deviation low limit [DL]
—
De-energized on deviation high and low
limits for target setpoint
Other [ETC]
Other [ETC]
—
Deviation within high and low limits for
target setpoint
Other [ETC]
Other [ETC]
—
Deviation high limit with stand-by
actions for setpoint
Other [ETC]
Deviation high limit [DH]
—
Deviation low limit with stand-by actions
for setpoint
Other [ETC]
Deviation low limit [DL]
—
De-energized on deviation high limit
alarm with stand-by actions for target
setpoint
Other [ETC]
Deviation high limit [DH]
—
De-energized on deviation low limit
alarm with stand-by actions for target
setpoint
Other [ETC]
Deviation low limit [DL]
—
Deviation high or low limit with stand-by
actions for setpoint
Other [ETC]
Other [ETC]
—
Deviation within high and low limits with
stand-by actions for target setpoint
Other [ETC]
Other [ETC]
—
Target SP high limit
Other [ETC]
SP high limit [H]
—
Target SP low limit
Other [ETC]
SP low limit [L]
—
Cooling-side control output high limit
Other [ETC]
—
Output high limit [H]
Cooling-side control output low limit
Other [ETC]
—
Output low limit [L]
Analog input PV high limit
Other [ETC]
—
—
Analog input PV low limit
Other [ETC]
—
—
Analog input RSP high limit
Other [ETC]
—
—
Analog input RSP low limit
Other [ETC]
—
—
Analog input AIN2 high limit
Other [ETC]
—
—
Analog input AIN2 low limit
Other [ETC]
—
—
Analog input AIN4 high limit
Other [ETC]
—
—
Analog input AIN4 low limit
Other [ETC]
—
—
Feedback input high limit
Other [ETC]
—
—
Feedback input low limit
Other [ETC]
—
—
Displayed in brackets ([ ]) on DAQLOGGER and Remote Monitor.
Furthermore, for the VJ series, all alarm types are Other [ETC].
Alarm types are loaded from each connected device upon start of acquisition by
GateCONTROL. Even if alarm types are changed on the connected device after
acquisition starts, the alarm types valid upon start of acquisition are used.
The number of UT551 and UT520 alarms is four (fixed). To ensure compatibility, also set
the number of UT55A and UT52A alarms to four.
The number of UT351 and UT321 alarms is three (fixed). To ensure compatibility, also
set the number of UT35A and UT32A alarms to three.
The number of UP550 and UM331 alarms is four (fixed). To ensure compatibility, also set
the number of UP55A and UM33A alarms to four.
The number of UP35A alarms is two (fixed).
3.3 Detals on Functons