Setup example (3) of 0 to 10 v input – Yokogawa µR10000 User Manual
Page 36
36
IM 04P01B01-02E
Selecting the Unit
16.
Use the
CHARACTER
key and
key to set
unit character and then press the
key. (For the procedure, see “Entering Characters” on page 23. For the characters
that can be used, see “Explanation” on page 38).
Unit:
CHR:%-
Finishing the Unit Setting
17.
When
Setting complete screen is displayed, press the ESC key.
03-03 Channel
Setting complete
18.
Hold down the
MENU
key for 3 seconds to return to Operation mode.
Setup Example (3) of 0 to 10 V Input
Set channel 04 to 0 to 10 V input and measure the range 0.0 to 400.0 m
3
/h. The 20 V DC
voltage range is used. The unit is converted using the linear scaling function. The scaling
range is –20000 to 30000 excluding the decimal point.
The measured values in the range of 0.0 to 400.0 m
3
/h are recorded in a width of 100
mm on the chart paper.
–20 V
20 V
Linear scaling Measurable range of 20 V
0.0 m
3
/h
400.0 m
3
/h
(Scale left)
100 mm
(Scale right)
0.00 V
10.00 V
(Span left)
(Span right)
Chart paper
Entering Setting Mode
1.
Hold down the
MENU
key for 3 seconds to enter Setting mode.
Selecting the Range
2.
Press the key with
Range shown on the screen.
Set=Range
Input range and
Displays a description of the setup item.
Selecting the Channel Range
3.
Press the
key to set the first channel to
04, and then press the key.
First channel Last channel
CH=04-04
First channel 01-
Displays the selectable range of channels.
4.
Likewise, set the last channel to
04 and then press the key.
* When the key, key, or
CHARACTER key is pressed while holding down the SHIFT key, the
operation is reversed as when the respective key is pressed by itself.
Setting the Input Range and Alarm on Measurement Channels