3. OPERATION
IM 01C50T01-01E
3-2
Table 3.1 Parameters list
Item
Description
Page
HART
Communicator
Tag number, up to 8 characters
Extension of Tag, up to 8 characters
Up to 16 characters
Up to 32 characters
mm/dd/yy
To describe a serial number of sensor.
0 to 16777215
°
C, K,
°
F,
°
R (Note 1)
Set the calibration range using the keypad.
Value for 4 and 20 mA signal is set with actual input applied.
Adjust the output response speed of the 4 to 20 mA DC.
Enter integer value from 0 to 99 seconds.
Set the % of PV where the damping function is disabled.
When PV exceeds this value, the damping is disabled and
the output follows the PV.
Specify the value to be used as PV from: “Sensor1”,
“Terminal Temperature(Term)” and “Sensor1-Term”. The SV,
TV and 4V can also be specified and monitored from the
HART communicator or Integral Indicator.
The YTA320 variables include above plus: “Sensor2”,
“Sensor2-Term”, “Average” and “Differential temperature”.
When using differential value, select whichever is desired;
Sensor1-Sensor2 or Sensor2-Sensor1.
Specify input type.
Specify the number of wire for RTD or ohm input.
Select a unit from
°
C, K,
°
F, or
°
R. (See note 1). This unit is
automatically referred as a PV, SV, TV or 4V unit when
Sensor1 is mapped.
Enable / disable sensor matching function. When it is set to
“enable”, sensor coefficient parameter can be entered.
Sensors specific co-efficients (by Callender vanDusen or
IEC)
Select a unit from
°
C, K,
°
F, or
°
R. (See note 1). This unit is
automatically referred as a PV, SV, TV or 4V unit when
Terminal Temperature is mapped.
Select CJC function
Specify constant value to be used for CJC function.
Specify input type.
Specify the number of wires.
Select a unit from
°
C, K,
°
F, or
°
R. (See note 1). This unit is
automatically referred as a PV, SV, TV or 4V unit when
Sensor2 is mapped.
Enable/disable sensor matching function. When it is set to
“enable”, sensor coefficient parameter can be set.
Sensors specific co-efficients (by Callender vanDusen or
IEC)
Enables/disables sensor back-up mode.
Shows the back-up status.
Enables the recovery from Sensor2 to sensor1 in back-up
operation.
Tag
Tag Ex
Descriptor
Message
Date
Sensor1(2)
snsr s/n
PV units
(SV,TV,4V)
LRV/URV
Apply values
PV Damp
(SV,TV,4V)
PV damp point
PV is
(SV,TV,4V)
Diff direction
(YTA320 only)
Snsr1 Type
Snsr1 Wire
Snsr1 unit
Snsr1 Match
Enbl
Snsr1 Match
coefs
Term unit
CJC Select
CNST CJC
Temp
Snsr2 Type
Snsr2 Wire
Snsr2 unit
Snsr2 Match
Enbl
Snsr2 Match
coefs
Enbl Snsr Bkup
Bkup state
Bkup Return
Snsr1
Memory
Process Variable
Sensor1
Configuration
Terminal
Temperature
Sensor2
Configuration
(YTA320 only)
Engineering Unit
Range
Damping time
constant
PV damping
holding point
Variable
mapping
Differential
Direciton
Sensor1 type
Sensor1 wire
Sensor1 unit
Sensor matching
function (Note 2)
Terminal Temp.
unit
CJC Function
Sensor2 type
Sensor2 wire
Sensor2 unit
Sensor matching
function (Note 2)
Sensor Back-up
Function
(YTA320 only)
T0301_1.EPS
Note 1:
°
F and
°
R are available only when option code /D2 is specified.
Note 2:
The parameters are available only when option code /CM1 is specified with YTA310/YTA320.
3-11
3-11
3-11
3-11
3-11
—
3-8
3-9
3-10
3-10
3-10
3-6
3-8
3-5
3-5
3-5
3-17
3-17
—
3-18
3-18
3-5
3-5
3-5
3-17
3-17
3-16
3-16
3-16