10-3
10. GENERAL SPECIFICATIONS
10.2
Model and Suffix Codes
᭹Model EJA310A
. . . . . . . . . . . . . . . . . . . . .
-D . . . . . . . . . . . . . . . . . . .
-E . . . . . . . . . . . . .
(Note 1)
-F . . . . . . . . . . . . .
(Note 4)
-G . . . . . . . . . . . . .
(Note 5)
L . . . . . . . . . . . . . . . . . .
M . . . . . . . . . . . . . . . . . .
A . . . . . . . . . . . . . . . . . .
S . . . . . . . . . . . . . . . . .
0 . . . . . . . . . . . . . . . .
1 . . . . . . . . . . . . . . . .
2 . . . . . . . . . . . . . . . .
3 . . . . . . . . . . . . . . . .
4 . . . . . . . . . . . . . . . .
5 . . . . . . . . . . . . . . . .
A . . . . . . . . . . . . . .
B . . . . . . . . . . . . . .
C . . . . . . . . . . . . . .
-2 . . . . . . . . . . . . .
-3 . . . . . . . . . . . . .
-6 . . . . . . . . . . . . .
-7 . . . . . . . . . . . . .
-8 . . . . . . . . . . . . .
-9 . . . . . . . . . . . . .
0 . . . . . . . . . . . .
2 . . . . . . . . . . . .
3. . . . . . . . . . . .
4 . . . . . . . . . . . .
5. . . . . . . . . . . .
7 . . . . . . . . . . . .
8 . . . . . . . . . . . .
9 . . . . . . . . . . . .
A . . . . . . . . . . . .
C . . . . . . . . . . . .
D . . . . . . . . . . . .
D . . . . . . . . . . .
E . . . . . . . . . . .
N
. . . . . . . . . . .
A . . . . . . . . .
B . . . . . . . . .
J . . . . . . . . .
C . . . . . . . . .
D . . . . . . . . .
K . . . . . . . . .
N . . . . . . . . .
Model
Description
EJA310A
Output Signal
Measurement span
(capsule)
Wetted parts material
Process connections
Bolts and nuts material
Installation
Electrical connection
Integral indicator
Mounting bracket
Optional codes
Absolute pressure transmitter
4 to 20 mA DC with digital communication (BRAIN protocol)
4 to 20 mA DC with digital communication (HART protocol)
Digital communication (F
OUNDATION
Fieldbus protocol)
Digital communication (PROFIBUS PA protocol)
0.67 to 10 kPa {5 to 75 mmHg}
1.3 to 130 kPa {9.6 to 960 mmHg}
0.03 to 3 MPa {0.3 to 30 kgf/cm
2
}
[Body]
(Note 3)
[Capsule]
[Vent plug]
SCS14A
SUS316L
(Note 2)
SUS316
without process connector (Rc1/4 female on the cover flanges)
with Rc1/4 female process connector
with Rc1/2 female process connector
with 1/4 NPT female process connector
with 1/2 NPT female process connector
without process connector (1/4 NPT female on the cover flanges)
[Maximum working pressure]
(L capsule)
(M capsule)
(A capsule)
SCM435
10 kPa abs
130 kPa abs
3 MPa abs
{75 mmHg abs}
{960 mmHg abs}
{30 kgf/cm
2
abs}
SUS630
10 kPa abs
130 kPa abs
3 MPa abs
{75 mmHg abs}
{960 mmHg abs}
{30 kgf/cm
2
abs}
SUH660
10 kPa abs
130 kPa abs
3 MPa abs
{75 mmHg abs}
{960 mmHg abs}
{30 kgf/cm
2
abs}
Vertical impulse piping type, right side high pressure, process connector upside
Vertical impulse piping type, right side high pressure, process connector downside
Vertical impulse piping type, left side high pressure, process connector upside
Vertical impulse piping type, left side high pressure, process connector downside
Horizontal impulse piping type, right side high pressure
Horizontal impulse piping type, left side high pressure
G1/2 female, one electrical connection
1/2 NPT female, two electrical connections without blind plug
Pg 13.5 female, two electrical connections without blind plug
M20 female, two electrical connections without blind plug
G1/2 female, two electrical connections and a blind plug
1/2 NPT female, two electrical connections and a blind plug
Pg 13.5 female, two electrical connections and a blind plug
M20 female, two electrical connections and a blind plug
G1/2 female, two electrical connections and a SUS316 blind plug
1/2 NPT female, two electrical connections and a SUS316 blind plug
M20 female, two electrical connections and a SUS316 blind plug
Digital indicator
Digital indicator with the range setting switch
(None)
SECC Carbon steel
2-inch pipe mounting (flat type)
SUS304
2-inch pipe mounting (flat type)
SUS316
2-inch pipe mounting (flat type)
SECC Carbon steel
2-inch pipe mounting (L type)
SUS304
2-inch pipe mounting (L type)
SUS316
2-inch pipe mounting (L type)
(None)
/
ᮀ Optional specification
Suffix Codes
T1006.EPS
Example: EJA310A-DMS5A-92NN/
ᮀ
Note 1: Refer to IM 01C22T01-01E for HART Protocol version.
Note 2: Diaphragm; Hastelloy C-276. Other wetted parts materials; SUS316L.
Note 3: Body; Material of cover flanges and process connectors.
Note 4: Refer to IM 01C22T02-01E for Fieldbus communication.
Note 5: Refer to IM 01C22T03-00E for PROFIBUS PA communication.