Yokogawa EJA440E User Manual
Page 34
<5. Parameter Summary>
5-2
IM 01C25T03-01E
No. Parameter name
Item
*
1
R/W
Content
Default value
Applicable
model
U
pl
oa
d
da
ta
F
P
L
D
AUX SET 1
Auxiliary setting data 1
D10 LOW CUT
Low cut
W 0.00 to 20.00%
10.00%
D11 LOW CUT MODE Low cut mode
W LINEAR or ZERO
LINEAR
D15 H/L SWAP
Impulse piping accessing
direction
W NORMAL or REVERSE
NORMAL
—
D16 H2O UNIT SEL
H2O unit select
W @4degC or @20degC
(68.0F)
@4degC
D20 OUT LIMIT (L)
Low side output limiter
W -2.50 to 110.00%
-2.50%
D21 OUT LIMIT (H)
High side output limiter
W -2.50 to 110.00%
110%
D22 REV OUTPUT
Output reversal
W NORMAL or REVERSE
NORMAL
D25 BURNOUT
CPU error
R
HIGH or LOW
—
D26 ERROR OUT
Hardware error
W BURNOUT DIR or HOLD
BURNOUT DIR
D30 SP UNIT
Static pressure unit
W See C20
MPa
—
D31 SP A/G SLCT
Gauge/Abs select for static
pressure
W GAUGE or ABSOLUTE
ABSOLUTE
—
D32 ATM. PRESS
Coefficient for given gauge
pressure
W Unit specified in D30
0.10133 MPa
—
D33 SP LRV
Lower limit of static pressure
W -32000 to 32000 within
measurement range
0.0 MPa
—
D34 SP URV
Upper limit of static pressure*
2
W -32000 to 32000 within
measurement range
—
D35 SP POINT
Decimal place of static
pressure
W 0 to 4
1
—
D36 SP DAMPING
Damping time constant of SP
W 0.00 to 100.00 seconds
2.00 seconds
—
D37 SP SELECT
H/L select for static pressure
W HIGH or LOW
HIGH
—
D40 TEMP UNIT
Temperature setting unit
W degC, degF, or K
degC
D50 QUICK RESP
Quick response
W OFF or ON (enable 0.00 to
0.50 seconds at C30)
OFF
D55 WRT PROTECT
Write protect indicator
R
NO or YES
NO
—
D56 WRT ENABLE
Write protect release
W 8 alphanumeric characters
None
—
D57 NEW PASSWORD User set password for write
protect
W 8 alphanumeric characters
None
—
D58 SOFTWR SEAL
Software seal
R
BREAK or KEEP
KEEP
—
D60 SELF CHECK
Self-diagnostics
R
See A60
—
E
AUX SET 2
Auxiliary setting data 2
E10 T. ZERO CMP
Temperature compensation
mode
W OFF or ON
OFF
—
E11 TEMP ZERO
Zero shift compensation
W -99.999 to 99.999%/degC
0.000%/degC
—
E30 BI DIRE MODE
Bidirectional mode
W OFF or ON
OFF
—
E50 DO SELECT
Contact output select
W INHIBIT, PRES, SP, TEMP,
PRES/SP, PRES/TEMP, SP/
TEMP, or PRES/SP/TEMP
INHIBIT
—
E51 DO SIG. TYPE
Signal type select
W OFF WHEN ALARM or ON
WHEN ALARM
ON WHEN
ALARM
—
E52 D OUTPUT
Contact output
R
OFF or ON
OFF
—
E60 SELF CHECK
Self-diagnostics
R
See A60
—
*1: R/W: R = Read only, W = Read & Write
*2:
The default value shows MWP (Maximum working pressure) of the capsule.
Since the working pressure limit varies according to the Model, refer to the General Specifications section in each user’s manual.