5) output signal low cut mode setup – Yokogawa EJA440E User Manual
Page 16
<3. Operation>
3-8
IM 01C25T03-01E
(4) Output Mode and Integral Indicator
Display Mode Setup
(C40: OUTPUT MODE, I20: P DISP
MODE)
The mode setting for the output signal and the
integral indicator can be performed independently.
This mode is set as specified in the order when the
instrument is shipped. Follow the procedure below
to change the mode.
If the instrument is equipped with an integral
indicator and the display mode is
SQUARE ROOT,
“ ” is displayed on the integral indicator.
• Output mode for 4-20 mA output
• Example: Set output mode from
Linear to
Square root.
ESC
SET
C40:OUTPUT MODE
SQUARE ROOT
FEED
NO
OK
SET
C40:OUTPUT MODE
LINEAR
< LINEAR >
< SQUARE ROOT >
Use the or key
to select
SQUARE ROOT.
Press the key twice to
enter the setting.
Press the (OK) key.
F0316.ai
• Integral indicator display mode
• Example: Set display mode from
Linear to
Square root.
ESC
SET
I20:P DISP MODE
SQUARE ROOT
FEED
NO
OK
SET
I20:P DISP MODE
LINEAR
< LINEAR >
< SQUARE ROOT >
Use the or key
to select
SQUARE ROOT.
Press the key twice to
enter the setting.
Press the (OK) key.
F0317.ai
(5) Output Signal Low Cut Mode Setup
(D10: LOW CUT, D11: LOW CUT MODE)
Low cut mode can be used to stabilize the output
signal near the zero point. The low cut point can
be set in a range from 0 to 20%, the direct ratio
corresponding to the output signal of 4 to 20 mA.
(Hysteresis: ±10% of the cut point)
Either
LINEAR or ZERO can be selected as the low
cut mode. Unless otherwise specified, the cut mode
is set to LINEAR at the factory.
Note that when the output modes of the output
signal and the integral indicator are selected as
SQUARE ROOT and LINEAR accordingly, the low
cut function is not available for the integral indicator
display.
• Example: Change the low cut setting range
from 10% to 20%, and the low
cut mode from
LINEAR to ZERO in
the SQUARE ROOT output mode.
FEED
NO
OK
SET
D11:LOW CUT MODE
ZERO
Use the or key
to select
ZERO.
Press the key twice to
enter the setting.
Press the (OK) key.
F0318.ai
FEED
NO
OK
SET
D10:LOW CUT
20.00 %
ESC
SET
D11:LOW CUT MODE
LINEAR
< LINEAR >
< ZERO >
DATA
DIAG
PRNT
ESC
PARAM
D10:LOW CUT
20.0 %
D11:LOW CUT MODE
ZERO
D15:H/L SWAP
NORMAL
CLR
ESC
SET
D10:LOW CUT
10.00 %
+ 20.00
Set
20.
Press the key twice to
enter the setting.
Press the (OK) key.
Next, the [D11: LOW CUT MODE]
setting panel is displayed.
(%)
50
20
0
50 (%)
Output
● Low cut mode “LINEAR”
Input
(%)
50
20
0
50 (%)
● Low cut mode “ZERO”
LOW CUT at 20%
Input