System Installation

Pump Specific Installation

RLM-W for Wayne/Dresser Electronic Dispenser

Note all warnings at the beginning of installation section.

1.

Plug the adapter cable (supplied by PIE) into the adapter port on

the RLM-W.

2.

Locate the Wayne/Dresser distribution box and wire the other end

of the adapter cable for W/D into the unused pump positions in

the DBox. In the event that the DBox is full, wire in “series” with

existing pump. The following chart shows wire color to function.

Wire Color

Function

Black

Loop 1 -

Red

Loop 1 +

Green

Loop 2 -

White

Loop 2 +

On Wayne/Dresser DBoxes with pumps wired into one side of the

DBox board, only one loop needs to be connected. For units with

both sides of the DBox board wired, Loop 1 and Loop 2 must

both be connected. Refer to next page for typical installation