Pump specific installation – Progressive International Electronics RLM User Manual
Page 37

RLM
Progressive International Electronics
Page 28
Version 1.1 / November 98
rlminstl.mnl
System Installation
Pump Specific Installation
RLM-W for Wayne/Dresser Electronic Dispenser
Note all warnings at the beginning of installation section.
1.
Plug the adapter cable (supplied by PIE) into the adapter port on
the RLM-W.
2.
Locate the Wayne/Dresser distribution box and wire the other end
of the adapter cable for W/D into the unused pump positions in
the DBox. In the event that the DBox is full, wire in “series” with
existing pump. The following chart shows wire color to function.
Wire Color
Function
Black
Loop 1 -
Red
Loop 1 +
Green
Loop 2 -
White
Loop 2 +
On Wayne/Dresser DBoxes with pumps wired into one side of the
DBox board, only one loop needs to be connected. For units with
both sides of the DBox board wired, Loop 1 and Loop 2 must
both be connected. Refer to next page for typical installation
drawing where 2 loops are needed.